• 48V/350A Telecom Power Supply System with Controller (N+1 redundancy)
  • 48V/350A Telecom Power Supply System with Controller (N+1 redundancy)
  • 48V/350A Telecom Power Supply System with Controller (N+1 redundancy)

48V/350A Telecom Power Supply System with Controller (N+1 redundancy)

Output Type: Single
Warranty: 2 Years
Output Power: 18725W
Input Voltage: Full Range
Connection Mode: Parallel Switching Power Supply
Starting Mode: Separate-excited Switching Power Supply
Samples:
US$ 1200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GPE48350E
Voltage Regulating Mode
Width Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
CE, UL, RoHS, ISO, CCC, CB
Brand
Gold Power
Transport Package
Carton
Specification
19′′ 9U
Trademark
GOLD POWER
Origin
China
HS Code
8504401990
Production Capacity
1000000 Sets/Year

Product Description

48V/350A Telecom Power Supply System with Controller (N+1 redundancy)

GPE48350E Embedded Power System
          
 Input: 90~280Vac; Output: -42~-58Vdc

Main features
  1. Wide operating range of AC input voltage: 90~290Vac
  2. Operating temperature range: -25ºC~+55ºC
  3. Zero current/voltage switching tech with high efficiency ≥91%
  4. Perfect battery management, battery temperature compensation, battery capacity test ,LVLD and LVBD protection, anti-reverse connective protection
  5. Hot-swappable
  6. Input over/under voltage protection
  7. Output over voltage protection
  8. Output over current protection
  9. Output short circuit protection
  10. Auto current sharing, parallel operation


48V/350A Telecom Power Supply System with Controller (N+1 redundancy)
48V/350A Telecom Power Supply System with Controller (N+1 redundancy)


48V/350A Telecom Power Supply System with Controller (N+1 redundancy)
The GPE48350E system consists of distribution unit, rectifier module (up to 7 sets) and monitoring module. The configuration is optional, as following table:
Configuration Rectifier Module Monitoring Module Distribution Remark
Standard GPR4850D
or
GPR4850E
 
7pcs (max.)
GPM48P (With Ethernet Port) AC distribution: 3-phase, 4-wire input,  3-pole AC breaker @ general line (63A);
DC distribution: Battery fuse 125A/2P;
LVLD: 63A×4 32A×3 16A×4
(MCB capacity could change)
LVBD: 16A×6
(MCB capacity could change)
For details, please refer to the specifications of modules.
 
Input
Parameters Min. Typ. Max. Unit Remark
Input voltage range 90 220 285 Vac  
Input frequency 45 50 65 Hz  
Input current     40 A  
Power factor 0.98        
Input over voltage protection 300     Vac Auto-recovery
Input over voltage recovery 280     Vac hysteresis width ≥5V
Input low voltage protection     85 Vac Auto-recovery
Input low voltage recovery     90 Vac hysteresis width ≥5V
Input over current protection         MCB at input side as protection
Output
Parameters Min. Typ. Max. Unit Remark
Output voltage range 42  53.5 58 Vdc  
Output current range 0     350 A 176~285VAC
0   75 A 90~175VAC
Output power 0 18725   W 176~285VAC
total power=load power + battery power
0 9350   W 90~175VAC
Ripple (Vp-p)     200 mv Rated input/output, apply 0.1uF film capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz.
Output efficiency 91 92   % 220Vac input
83     % 110Vac input
Output over voltage protection 58.5   60.5 Vdc Lock up
Output current limit protection         Available
Output short-circuit protection         Long time short-circuit no damage, auto-recovery
Over temperature protection         Auto-recovery when ambient temperature <65ºC
LVD         2 LVD available, 1 for critical loads, 1 for battery bank
Battery anti-pole protection         Battery and power supply no damage
Voltage regulation     ±1 %  
 
Basic output features  (form 2)
Parameters Min. Typ. Max. Unit Remark
Temperature coefficient     ±0.2 ‰/ºC  
Current share unbalance range     ±5 % @50~100% load
System on-off Inrush voltage     ±5 % When plug out any rectifier module(load current should be higher than total rectifier output current), system voltage fluctuation
dynamic response     200 uS 25%~50%~25% load change
50%~75%~50% load change
dynamic response adjustment     ±5 % Rated output voltage, rated load current
Start power rise time 3   8 S Time between system power on to rectifier output voltage rise to rated value
Inner voltage reduce     500 mV  

About us:
48V/350A Telecom Power Supply System with Controller (N+1 redundancy)
48V/350A Telecom Power Supply System with Controller (N+1 redundancy)
48V/350A Telecom Power Supply System with Controller (N+1 redundancy)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now