• 48V Input & AC Ouput Telecom Pure Sine Wave Inverter
  • 48V Input & AC Ouput Telecom Pure Sine Wave Inverter
  • 48V Input & AC Ouput Telecom Pure Sine Wave Inverter

48V Input & AC Ouput Telecom Pure Sine Wave Inverter

Nature of Source Flow: Active Inverter
Certification: CCC, ISO9001, RoHS, CE
Output Power: 2000va
Grid Type: off-Grid Inverter
Output Type: Multiple
Circuit Topologies: Full-Bridge Type
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GPDA2000VA-E
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Transport Package
Carton
Specification
481.6x270x88.1mm
Trademark
GOLD POWER
Origin
China
HS Code
8504401990
Production Capacity
6000000 PCS/Year

Product Description

 
48V input & AC ouput telecom pure sine wave inverter
GPDA2000VA-E
Input: 40 - 57.6 Vdc; Output: 220 Vac;Rated Capacity: 2000VA
Environmental requirements
Parameter Min. Typical Max. Unit Note
Operating ambient temperature - 5   +40 ° C  
Inverter temperature storage environment - 25   +70 ° C  
Relative humidity 0   95 % Relative humidity, no condensing
Altitude     3000 m Meet GB3859.2-93 derating requirements.
Cooling Fan cooling
Work Environment No conductive dust explosion, corrosion and destruction of gases and vapors, no severe vibration and shock.
 
 Input
Parameter Min. Typical Max. Unit Note
DC operating voltage range 40   58 Vdc Input DC voltage error ± 1V
DC start-up Range 43   56    
Input rated voltage   48   Vdc  
Input Current     65 A Rated input, rated output
Start-up input Max Surge Current     150 A  
AC bypass startup range 200   240 Vac  
AC bypass operating voltage range 180   260 Vac  
 
Output
Parameter Min. Typical Max. Unit Note
Rated output voltage   220   Vac  
Rated output current   7.72   A Power Factor 0.8
Output regulation     ± 5 %  
Rated output frequency 49 50 51 Hz  
Rated Capacity     2000 VA  
Rated output power   1600   W  
Efficiency   88   % Rated operating conditions
Output power factor   0.8     Rated operating conditions
Dynamic transient recovery time     100 ms  
 
 
Voltage waveform Sine wave THD <3% (linear load)
Sine wave THD <8% (Non-linear load)
Over load capacity 105 ~ 125% for no less than 60 s, 125 ~ 150% last not less than 1 0 s
Output current peak-peak coefficient 3: 1
Output A wiring row output
Working Mains priority; when the mains over/under voltage or power down, the bypass start up, time≤5ms. When the mains working normally, mains start up, time≤5ms.

48V Input &amp; AC Ouput Telecom Pure Sine Wave Inverter

48V Input &amp; AC Ouput Telecom Pure Sine Wave Inverter





48V Input &amp; AC Ouput Telecom Pure Sine Wave Inverter

 
Protection
Parameter Min. Typical Max. Unit Note
DC input under voltage protection set point 37   40 Vdc Test with half load
DC input under voltage recovery set  point 40   43 Vdc Reach the recovery value, auto-recovery.
DC input over voltage protection set point 58   60 Vdc Test with half load
DC input over voltage recovery set point 56   58 Vdc Reach the recovery value, auto-recovery.
Bypass input under voltage protection set point 160   180 Vdc Test with half load
Bypass input over voltage protection set point 260   280 Vdc Test with half load
Over Temperature Protection Power supply with over-temperature protection. When the temperature inside the main radiator, reaching over temperature protection set point, turn off the output, temperature hysteresis of 1 0 ºC or so.
Anti-reverse protection Power supply with input anti-reverse protection. When the input  reverse polarity, the power stop working, and no damage.
Short circuit protection Power supply with output short circuit protection. Short circuit is detected, the output power is turned off and an alarm signal every 30 seconds automatically restart once the fault is removed, auto-recovery. Long-term short circuit, power off lock, reboot to work.
Over current protection Power supply with output over current protection. Over current is detected, the output power is turned off and an alarm signal when the load back to the rated value, auto-recovery. Long-term overload, power off lock up, reboot to resume normal work.
Alarm (buzzer alarm) DC input abnormal, overload, short circuit, inverter fault, the buzzer alarm and warning light on.

About us:

48V Input &amp; AC Ouput Telecom Pure Sine Wave Inverter