| Input | |||||||||||||||
| Parameter | Min. | Typ. | Max. | Unit | Remark | ||||||||||
| AC input voltage range | 100 | 110/220 | 264 | Vac | |||||||||||
| AC input voltage frequency | 47 | 50/60 | 63 | Hz | |||||||||||
| Power factor | 0.95 | 220Vac full load | |||||||||||||
| Input inrush current | 40 | A | 220Vac full load/cold status | ||||||||||||
| AC input mode | Single phase | Support single phase | |||||||||||||
| Output | |||||||||||||||
| Parameter | Min. | Typ. | Max. | Unit | Remark | ||||||||||
| Output voltage range A | 33 | 44 | 48 | Vdc | Auto Adaptive | ||||||||||
| Output voltage range B | 38 | 52 | 54 | Vdc | Auto Adaptive | ||||||||||
| Output current range A | 3.13 | 12.5 | A | Full voltage input range | |||||||||||
| Output current range B | 2.72 | 11.12 | A | Full voltage input range | |||||||||||
| Load regulation | ±2 | % | Rated voltage input, full load | ||||||||||||
| Constant current Dimmable output |
±5 | % | Off = Lamp off 25% = 3.13A +/- 10% 50% = 6.26A +/- 10% 75% = 9.39A +/- 10% 100%= 12.5A +/- 10% EXT = 0~10V dimming RJ11 socket <1.5+/-0.5V, Off >2V+/-0.5V, On 2~10Vdc reflects output current 20~100% (+/-10%) Linearity < 10% |
||||||||||||
| Source regulation | ±0.5 | % | Rated current output, full input | ||||||||||||
| Noise + Ripple (peak to peak) | <=5% | mV | Rated full in/output range | ||||||||||||
| Output power | 800 | W | |||||||||||||
| Output efficiency | 88 | 94 | 95 | % | 240Vac input, full load, normal ambient | ||||||||||
| Dynamic response overshoot | ±5 | % | 25%-50%-25% or 50%-75%-50% load change, current changing rate: 0.1A/us,cycle:4ms | ||||||||||||
| Dynamic response overshoot | ±10 | % | |||||||||||||
| Temperature coefficient | ±0.02 | %/ºC | Rated output voltage and output current, full range working temperature | ||||||||||||
| Turn-on output delay | 3 | S | Test at 220Vac full load | ||||||||||||
| Turn on/off overshoot | ±5 | % | Full voltage input range, full load output | ||||||||||||
| Output voltage rising time | 100 | 200 | ms | Rated input/rated output | |||||||||||
| Protection | |||||||||||||||
| Parameter | Min. | Typ. | Max. | Unit | Remark | ||||||||||
| Input low voltage protection | 70 | 80 | V | Half-load | |||||||||||
| Input low voltage recover | 80 | 90 | V | Half-load | |||||||||||
| Input over voltage protection | 275 | 305 | V | Half-load | |||||||||||
| Input over voltage recover | 265 | 290 | V | Half-load | |||||||||||
| Output over voltage protection | 51 | 54 | 57 | V | Auto recovery | ||||||||||
| Output constant current point | 4.17 | 16.67 | A | ||||||||||||
| Output short circuit protection | Long term short circuit, auto recovery | ||||||||||||||
| Over temperature protection trigger point | 60 | 70 | ºC | Over temperature cut off, could recover. Output full load test, reference temperature is the ambient temperature. | |||||||||||
| Ambient | |||||||||||||||
| Parameter | Min. | Typ. | Max. | Unit | Remark | ||||||||||
| Operating temperature. | -20 | 40 | °C | ||||||||||||
| Storage temperature | -45 | 85 | °C | ||||||||||||
| Relative humidity | 5 | 95 | % | No condensing | |||||||||||
| Altitude | 0 | 5000 | m | ||||||||||||
| Cooling | Natural cooling | ||||||||||||||
| Safety & Insulation | |||||||||||||||
| Parameter | Standard requirements | Remark | |||||||||||||
| Input -output | 1500Vac/10mA//1min | No flashover or breakdown |
|||||||||||||
| Input - ground | 1500Vac/10mA//1min | ||||||||||||||
| Output - ground | 500Vdc/10mA//1min | ||||||||||||||
| Insulation resistance | ≥10MΩ | ||||||||||||||
| Leakage current | <0.75mA | 220Vac input 50Hz | |||||||||||||
| Grounded resistance | <0.1 Ω | Test current is 32A, time is 2S. | |||||||||||||
| EMC & Others | |||||||||||||||
| Conducted emission | EN55015 - Class A | ||||||||||||||
| Radiated emission | EN55015 - Class A | ||||||||||||||
| Surge | EN61000-4-5 input:line-line2KV,line-ground:4KV | ||||||||||||||
| ESD | EN61000-4-2 Contact discharge:±4KV, Air discharge:±8KV. (criterion B) | ||||||||||||||
| RS | EN61000-4-3 LEVEL 3;criterion A;10V/m field strength | ||||||||||||||
| CS | EN61000-4-6 (the power module output port also needs to be tested, criterion A;10V field strength | ||||||||||||||
| Fast transient pulse group. | ±2KV,LEVEL 3,criterion B IEC61000-4-4 | ||||||||||||||
| vibration | |||||||||||||||
| Impact | |||||||||||||||
| Voltage fluctuation and flicker. | Pst≤1.0 dc≤3%; P1t≤0.65 dmax≤4% the time of d(t)value more than 3.3% are no more than 200ms |
||||||||||||||
| Current harmonic emission | CLASS A IEC61000-3-2 6 | ||||||||||||||
| Noise | 55dB(A);testing distance:1m | ||||||||||||||
| MTBF | MTBF≥200,000h | ||||||||||||||
| Smell | No peculiar and deleterious odor | ||||||||||||||
| Mechanical | |||||||||||||||
| L * W * H (mm) | 372*109*72 mm | ||||||||||||||
| Weight(KG) | ≤2.6 KG | ||||||||||||||
![]() |
|||||||||||||||