400W, 5-50V 15A Customized Power Supply

Output Type: Single
Warranty: 2 Years
Output Power: 401 - 500W
Input Voltage: 90-264V VAC
Certification: CE, RoHS, CCC, CB, FCC
Brand: Goldpower
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GPAD301M50-1A
Transport Package
Carton
Trademark
Goldpower
Origin
China
HS Code
8504401400

Product Description

Welcome to use GPAD301M50-1A customized power supply from Goldpower. GPAD301M50-1A is a one-way output power supply with wide input voltage range and +5~50V wide adjustable output. Over-current protection, input under- voltage protection, output short-circuit protection, output over-voltage protection and current-sharing with parallel connection are functional. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technological equipment.







Safety rules:

 
 
High voltage!
Any touch with bare hand against high voltage at input side is forbidden.

Caution
The device shall be securely grounded before power-on.

High voltage!
Any operation at AC & high voltage under lightning is forbidden.


1.Specification

 
Environment
Parameter Min. Typ. Max. Unit Remark
Operation temperature -40   80 °C  
Storage temperature -20   100 °C  
Relative humidity 10   95 % Without condensing.
Atmospheric pressure 70   106 Kpa Normal operation.
Altitude -40   80 °C Nature cooling.
 
Input
Parameter Min. Typ. Max. Unit Remark
Input voltage range 85 220 264 Vac  
Input startup voltage range 90   264 Vac  
Input nominal voltage   220   Vac  
Input frequency range 45 50/60 65 Hz  
Power factor 0.95       Test with rated input, max. power output.
Input inrush current     20 A  
Input  max. current     5 A  
 
Output
Parameter Min. Typ. Max. Unit Remark
Output voltage range 5~50V 5   50 Vdc  
Output current & power range 5~20V 0   15 A  
20~50V 0   400 W Power limitation: 300W
Load regulation     ±2 %  
Stabilized voltage precision     ±1 %  
Regulation     ±1 %  
Load current-sharing -5   +5 % Test with 50%~100% rated output.
Ripple(Vp-p) 5~50V 5~12V  80 mV Rated input & output, test with a 0.1UF ceramic capacitor and a 10UF high-frequency electrolytic capacitor, bandwidth of 20MHz.
12~24V 100
24~50V 150
Pahse margin 5~50V       d 30V output45°;others30°
Magnitude margin 5~50V       dB 30V output-10dB;others-6dB
Load dynamic test Half-load transition   For output 5V-7V, less than±4%,
For output 8V-12V, less than±3%,
For output 13V-50V, less than±2%.
Output power   300 400 W  
Output efficiency   83   % Rated input, full-load output.
Temperature coefficient     ±0.02 %/ºC  
2~100V startup output delay     1.2 S  
Output voltage rise time     500 mS Startup with rated input & putput. Duration for the output rise from 10% to 90%, with output wave rising monotonously.
Capacitive load 2200     UF  
               
 
Protection
Parameter Min. Typ. Max. Unit Remark
Input over-voltage protection voltage 275   300 Vac Test with half-load.
Input over-voltage protection recovery voltage 270   290 Vac  
Input under-voltage protection voltage90 65   85 Vac Test with half-load.
Input under-voltage protection  recovery voltage90 75   90 Vac  
5~20V output current-limiting protection point 17   23 A Test with full-load , auto-recoverable.
20~50V output current-limiting protection point 410   450 W Test with full-load ,auto-recoverable.
5~50V Short-circuit protection         Long term shor-circuit endurable,auto-recoverable.
5~50V output over-voltage protection point 55   60 V Auto-recoverable.
 
EMC and others
Parameter Standard and requirement
CE EN55022:1998 - Class B
RE EN55022:1998 - Class B
SURGE IEC61000-4-5:1999,line-line  2KV,line-ground 4 KV  CLASS3
ESD IEC61000-4-2:2001   Contact discharge6KV, air discharge8KV. (criterion b)
RS IEC61000-4-3:2002
Testing intensity:
800MHz~1000M:
1.4GHz~2GHz: 3V/M
Amplitude modulation: 80%AM(1kHz) 
CS IEC61000-4-6:2001 
Testing frequency: 0.15 MH~80 MHz,
Testing intensity: 3V,
Amplitude modulation: 80%AM(1kHz)
EFT/B IEC61000-4-4:2004  ±2KV 
DIP IEC61000-4-11:1994 voltage dip to 70%UT,duration:500Ms; dip to 0%UT,duration:20mS; dip to 0%UT,duration:5000mS (criterionB)(criterionC)
Lightning current line-line/line-ground: 5kA
test with 8/20 μs waveform.
Vibration Frequency  Acceleration spectral density
1~4Hz: 0.0001g2/Hz;
4-100Hz : 0.01 g2/Hz;
100-200Hz: 0.001g2/Hz
Totall root mean square acceleration: 0.781Grms; test directions:3 axes. Duration:30min per axe.
Shock Waveform : half sine-wave; peak acceleration:300m/s2; pulse width :6ms;
test directions:6; 3times per direction.
Collision Waveform: half sine-wave; peak acceleration:180m/s2; pulse width :6ms; direction:6 directions; 100times per direction.
Drop Weight15kg   height:100cm
Drop at 1 angle, 3 edges and 6 surfaces:
1 angle: The weakest angle shall be selected for drop test, otherwise, angle 2-3-5
3 edges: those intersect at above angle
6 surfaces: External surfaces of packaged unit,
1 time per surface.
Reliability ( calculated) 200,000Hours
Acoustic noise 50dB
Odor No peculiar and deleterious odor
moisture proof GB/T2423.4-1993 ,24~45ºC,95%RH,48h
Mould proof GB/T2423.16-1999  CALLS 2
MTBF MTBF100,000H
 
Safety and Insulation Rating
Parameter Standard Remark
Input -output 3000Vac/10mA//60min No flashover or breakdown
The discharge tube shall be removed before test.
Input -ground 2000Vac/10mA//60min
output-ground 500Vdc/10mA//60min
Ground resistance <0.1Ω  
Insulation resistance 10MΩ At normal atmospheric pressure,
relative humidity: 90%; Testing voltage: 500v DC;  The insulation resistance of input-output,input-ground,output-ground shall not be less than 10MΩ.
Leakage current 3.5mA 264Vac