High voltage! |
Any touch with bare hand against high voltage at input side is forbidden. |
Caution | The device shall be securely grounded before power-on. |
High voltage! |
Any operation at AC & high voltage under lightning is forbidden. |
Environment | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operation temperature | -25 | 70 | °C | For high temperature of 60ºC-70ºC,with 80% load derating. | |
Storage temperature | -45 | 85 | °C | ||
Relative humidity | 10 | 95 | % | ||
Altitude | ≤5000 | m |
Input | ||||||
Parameter | Min. | Typ. | Max. | Unit | Remark | |
Input voltage range | 85 | 220 | 265 | Vac | Or 120-370VDC For convenience of certification,inpput voltage range on product label marked as 100-240 Vac. 85-265 Vac at testing . For low-voltage of 85-100Vac input,test with 80% load derating. |
|
Input frequency range | 47 | 50 | 63 | Hz | ||
Input power factor | 0.95 | % | 0.99@115VA,0.95@230VAC,full-load | |||
Input current | 5 | A | 3.5Adc | |||
Surge current | 30 | A | ≤20A@115VA,≤30A@230VAC | |||
Surge voltage | KV | line-ground 4KV,line-line 2KV(class A) | ||||
Drain voltage () |
115Vac | 0.25 | 0.75 | mA | ||
230Vac | 0.5 | |||||
Output | ||||||
Parameter | Min. | Typ. | Max. | Unit | Remark | |
Output voltage range | 20 | 24 | 28.8 | V | adjustable(20V~24V with 13A load,25V~26V with 11A load,26-28.8V with 9A load,for setting value and other specification test: 24V/13A.),The output voltage be in the range of 24±0.2V at delivery. | |
Output current range | 13 | A | Refer to stabilized current output range. | |||
Startup time | 5 | S | ||||
Load regulation | ±1 | % | ||||
Stabilized voltage precision | ±1 | % | ||||
Source regulation | ±1 | % | ||||
Ripple&noise | 150 | mV | mVp-p | |||
Output power range | 312 | W | full-load output | |||
Output indicator | φ5 | mm | Green light on when DC output normally | |||
Temperature coefficient | ±0.02 | %/ºC | ||||
full-load efficiency | 85 | % | 220Vac,full-load | |||
82 | 110Vac,full-load | |||||
Hold-up time | 20 | mS | 100V~240Vac,full-load,phase angle of 45°,duration for AC input powerdown to output voltage dip to 90% .. | |||
Capacitive load | 5000 | uF | The power supply shall startup normally and operate stably. | |||
Inductive load | ,,printer and so on | The power supply shall startup normally and operate stably. | ||||
Dynamic response | Recovery time | 500 | uS | 25%-50%-25%,0.25A/uS, cycle 2mS | ||
500 | uS | 50%-75%-50%,0.25A/uS, cycle 2mS | ||||
Overshoot amplitude | ±5 | % | 25%-50%-25%,0.25A/uS, cycle 2mS | |||
±5 | % | 50%-75%-50%,0.25A/uS, cycle 2mS | ||||
Protection | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input over-voltage protection voltage | 270 | 280 | 290 | V | Remove this function,but the power supply shall work stably for shorttime under 300Vac input |
Input over-voltage protection recovery voltage | 265 | 270 | 280 | V | |
Input under-voltage protection voltage | 65 | 75 | 80 | V | |
Output under-voltage protection recovery voltage | 75 | 85 | 90 | V | |
Output over-voltage protection | 30 | 34.8 | V | ||
Output over-current protection | 17 | A | Constant current,auto-recoverable. Conduct protection after 100ms when the current>17A, Vo before protection>16.8V, Vo after protection be less than 4V. |
||
Short-circuit protection | Protection when short-circuit,auto-recoverable. | ||||
Over-temperature protection | ºC | With over-temperature protection function. | |||
EMC and others | ||
Parameter | Standard and requirement | |
CE | EN55022:1998 - Class B (pure resistance load) | |
RE | EN55022:1998 - Class B (pure resistance load) | |
SURGE | IEC61000-4-5:1999,line-line 2KV,line-ground 4 KV (criterionA) | |
ESD | IEC61000-4-2:2001 Contact discharge:±6KV, air discharge:±10KV. (criterionA) | |
RS | IEC61000-4-3:2002 Test LEVEL 10V/m | |
CS | IEC61000-4-6:2001 Test LEVEL 10V | |
EFT/B | IEC61000-4-4:2004 LEVEL 3 B Class | |
Vibration & Impact | Vibration | 10Hz~55Hz,acceleration :19.6m/s2 3directions for 1hour |
Impact | Half sine-wave,peak acceleration :20G,pulse width :11m,S,X,Y,Z directions,3 times per direction. | |
Startup & shutdown impact | ≥1000 times,25ºC115Vac,full-load,3S/on,3S/off,without damage. | |
DIP | IEC61000-4-11:1994 voltage dip to 0%,duration:5000mS(250cycles );(criterionC) | |
IEC61000-4-11:1994 voltage dip to 70%,duration:500mS(25cycles );0°,45°,90°,135°,180°,225°,270°,315°Meet(criterionC) | ||
IEC61000-4-11:1994 voltage dip to 40%,duration:100mS(5cycles );0°,45°,90°,135°,180°,225°,270°,315°Meet(criterionC) | ||
IEC61000-4-11:1994 voltage dip to 0%,duration:10mS(0.5cycles );Meet(criterionB) | ||
Harmonic current | IEC 61000-3-2:2001 3 subharmonic current<2.3A,others refer to Standard(1.14,0.77,0.4,0.33,220,15*15/ n) | |
Voltage fluctuation & flicker | IEC61000-3-3:1994 Pst≤1.0,P1t≤0.65,relative stable voltage change≤3%,max.chage≤4%,duration for d(t) exceed 3% is less than 200mS | |
Cooling | Cooled by fan,keeping the inside temperature<+65ºC | |
Audible noise | ≤50dB;25ºCfull-load,test at 100cm | |
MTBF | MTBF≥100,000h,90V-14V,110V-14A,220V-14A,260V-14A | |
Safety | The chassis and heat sink are electrically neutral,without peculiar and deleterious odor. | |
Chassis | With earth poleφ4 | |
Safety and Insulation Rating | ||
Parameter | Standard | Remark |
Input -output | 3000Vac/10mA//60min | No flashover or breakdown The discharge tube shall be removed before test. |
Input -ground | 2000Vac/10mA//60min | |
output-ground | 500Vdc/10mA//60min | |
Ground resistance | <0.1Ω | |
Insulation resistance | ≥100MΩ | At normal atmospheric pressure, relative humidity: 90%; Testing voltage: 500v DC; The insulation resistance of input-output,input-ground,output-ground shall not be less than 100MΩ |
Contact current | To enclosure≤1.75mA to output≤0.25mA | 264V/60Hz |
Ground impedance | ≤0.1Ω 32A/2 min | |
PCB | Conform to UL94V-0 Standard | Inflaming retarding. |