Customization: | Available |
---|---|
Certification: | TUV, CE, RoHS |
Brand: | Goldpower |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.2input |
|||||
Parameter | Min | Typ. | Max | Unit | Remark |
AC input voltage range | 90 | 220 | 264 | Vac | |
AC input voltage frequency | 60 | A | |||
power factor | 60 | A | 220VAC input, output full load | ||
Input impulse current | 47 | 50 | 63 | Hz | Full range normal operation |
AC input system | 0.95 | 220VAC input, output full load |
2.2 output characteristic | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
output voltage | 12 | 45 | Vdc | Output voltage is set according to factory requirements | |
Output current range | 0 | 60 | A | ||
output power | 500 | W | |||
Output efficiency | 91 | % | 220VAC input, full load output | ||
Ripple (peak to peak) | 200 | m Vp-p | At the rated input / output, add one 0.1 μ f ceramic chip capacitor and one 10 μ f high frequency electrolytic capacitor, and measure the bandwidth at 20MHz. | ||
Load adjustment rate | ±2 | % | |||
Source adjustment rate | ±0.5 | % | |||
temperature coefficient | ±0.03 | %/ºC | |||
Switching machine overshoot | ±10 | % | |||
Dynamic response overshoot | ±5 | % | 25% - 50% - 25% or 50% - 75% - 50% load change, load mutation rate is 0.1a/μ s, calculated as the part beyond the output voltage stabilization accuracy range | ||
Dynamic response recovery time | 200 | ūS | |||
Power on output delay | 2 | S | Input 220VAC, output full load |