Chapter 1 Introduction
ZXB07.001 is a low duty power supply with AC/DC multiple outputs. Due to the latest circuit design, it is compact and of reliable performance. The whole system is of high regulation and output efficiency. The wide input voltage applicable to rural power network. The product is equipped with protection against output over-current, short circuit, protection, output over-voltage and over-temperature. The product is cooled by natural convection. It is designed according to the safety regulations, which strictly conforms to the safety standard of information technology.

Chapter 2 Technical Specification
2.1. Ambient Requirements
2.1.1
Item Unit Min Typ. Max Remark
Nominal operation temperature ºC -5 25 55 Safety approved.
Operation temperature ºC -25 25 65 The power system normally operates.
Relative humidity % 5   93 No condensing
Absolute humidity g/m3 0.26   25 No condensing
Altitude m - - - Operation atmospheric pressure: 70kPa~106kPa
Cooling
      
Natural cooling. The heat generated by customized power shall be conducted to the enclosure through contact with max temperature of 65ºC and the conduction section shall be 28555mm2.
Operating duration 24Hs continuous work.
2.1.2 Storage conditions
Item Unit Min Typ. Max Remark
Storage temperature ºC -40 - 80  
Relative humidity % 0 - 95  
Absolute humidity g/m3 0.03   30  
Altitude m 0   2000  
Temperation variation ºC/min     1  

2.2. Input Properties
Item Unit Min Typical Max. Remark
Rated input voltage Vac   220    
Input voltage range Vac 85 220 290 Nominal input voltage: 100-240Vac
Input frequency Hz 43 50 67  
Inrush current A     30 25ºC cold startup 290V input, full load
Input power factor   0.95     Rated full load
2.3. Output Electrical Properties
      1. Basic Output Properties
Output voltage Output voltage rating Output current Load Regulation Line regulation Regulation Vp-p
-54V -53.5~-54.5V 1.6A ≤±2% ≤±2% ≤±3% ≤±3%
3.4V 3.3~3.5V 7A ≤±2% ≤±2% ≤±3% ≤±3%

Remark:
  1. After operation under low temperature for 1 hour, the ripple (p-p) shall be measured with 1 10uF aluminum capacitor and 1 0.1uF filmy capacitor at output. The twisted pair is 20cm and within 20MHz bandwidth of oscillograph. There shall be no battery and backup power during the test.
  2. The system output current is 1.6A including the charge current (1A) under voltage of -54V. There shall be no battery and backup power during the test.
  3. -54V output shall be adjustable within -45~-54 under equalizing charge or discharge of battery.

  • Other Output Properties
Item Unit Min Typical Max. Testing Conditions
Output power W - 110.2    
110V Output efficiency % 80     Test with load of 2.5A at -54V and 8A at 3.4V. The ambient temperature is 25ºC.There shall be no battery and backup power during the test.
220V Output efficiency % 82      
Temperature coefficient /ºC     0.03%  
Over/under shoot @start up/shutdown       5%  
Transient response overshoot       5% Di/dt=10A/s, 25%~50%~75%Load variation with rate ≤0.1A/uS, calculated from the part out of the output line regulation range.
Transient response recovery duration μS     200
Turn on time S     4 Rated input/output
Output voltage boost duration mS     100 Rated input/output, boost from 10% to 90%
Capacitive load capability uF     1000 -54V
uF     4000 3.4V
3.4V power down delay mS 10     The input voltage keeps to 3.4V/8A. There shall be no battery and backup power during the test.
 
  • Battery management
Dual outputs are provided at battery interface for battery operation and -48V backup power input (Battery/backup power -48V common power point: -48VRTN/BAT+, -48V backup power, BAT-). Connect only the battery if there is only 220Vac input and connect the backup power when fed by both 220Vac and backup power. Two diodes are employed for isolation of -48V backup and -48V voltage transferred from 220ac.

Note: There shall be only green LED on for normal power supply form AC input and -48V backup. Other parameters are measured without backup power.
Schematic diagrams for above two situations:
Power supplied by 220V only:

Power supplied by 220V and backup:


The -54V and 3.4V outputs will be powered by battery under situation of AC mains failure and the normal operation duration under full configuration shall be not less than 4 hours. 
The system is functioned with secondary shutdown, however, the battery load is controlled by main devices. 48V lead acid battery is adopted for backup and the discharge is managed by system. Current limiting shall be conducted during battery charge, the ultimate charge current shall be 1A.
Item Requirement Remark
Float voltage 54V Regulation: ±2%
Current limiting for equalizing/float charge Equalize charge with voltage not more than -56V and then float charge. ≤1A
U/V alarm set point 46±1V Alarm through potential free contact
Power down protection set point 43.5±0.5V  
Leakage current Not supplied <0.35mA
Recovery set point From battery shutdown till the re-power on of rectifier AC input  
Temp. compensation coefficient Not supplied Not supplied
Battery capacity 7AH Default configuration (with charge capacity of 10-12AH)
Battery reversed polarity protection Supplied  
Battery current limiting Current limiting circuit is supplied for battery discharge The fuse will be blown at over current.


2.4. Protection
 
Item Unit Min Typical Max. Recovery Property
Input O/V protection set point V 290 310 320 Without battery and backup power
Input O/V recovery  set point V 290 300 320
Input O/V protection hysteresis V 8    
Input U/V protection set point V 60 65 85 Without battery and backup power
Input U/V recovery set point V 60 75 85
Input U/V protection hysteresis V 8    
-54V output O/V protection V -59 -62 -65 Lock up, without battery and backup power
3.4V output O/V protection V 3.7 3.95 4.2
-54V output over-current protection A 2.75 3 3.75 Auto-recoverable, without battery and backup power, 3.4V, with 8A full load
3.4V output over-current protection A 11 13 15 Auto-recoverable, without battery and backup power
Thermal protection ºC       Auto-recoverable, without battery and backup power
Short circuit protection A  Damage free under long-term short circuit, auto-recoverable, without battery and backup power
Input power failure alarm  
Auto-recoverable, without battery and backup power
Output protection requirement   Output protection at 3.3V shall not affect the output at -54V.




2.5. Safety and insulation rating
 
Item Rating Standard(or Testing condition)
Insulation voltage(output-GND) 500Vac 500Vac/1Min / Leakage current≤10mA, no breakdown or flashover
Insulation voltage (input -GND) 1500Vac 1500Vac/1Min / Leakage current≤10mA, no breakdown or flashover
Insulation voltage (input to output) 3000Vac 3000Vac/1Min / Leakage current≤10mA, no breakdown or flashover
Insulation resistance 10MΩ RH:<90%, DC 500V, the insulation resistance of input to output, input to ground, and output to ground is not less than 10MΩ.
Leakage current <3.5mA Max input operation voltage, 50Hz input

2.6. EMC

 
Item Requirement Standard
CE CLASS B for integrated and CLASS A for single equipment EN55022
RE CLASS B for integrated and CLASS A for single equipment EN55022
Harmonic current CLASS D IEC 61000-3-2[6]
CS Testing frequency: 0.15MHZ-80MHZ; Electric strength: 3V; AM: 80% (1KHZ) IEC61000-4-3 (Criterion A)
RS Testing frequency: 80MHZ-1000MHZ; Electric strength: 10V; AM: 80% (1KHZ) IEC 61000-4-6 (Criterion A)
ESD Air discharge: ±8KV IEC 61000-4-2 (Criterion A)
Contact discharge: ±6KV
Voltage ripple & flicker PST≤1.0;PLT≤0.65;dC≤3%;dmax≤4%;Vd(t) is 3% or less when the voltage ripple duration is more than 200ms IEC61000-3-3
 EFT/B ±2KV IEC61000-4-4 (Criterion B)
SURGE Basic: Wire-wire: 2Ω IR, ±1KV Wire-GND: 12Ω IR,±2KV (Criterion B)
Strengthening: Wire-wire: ±4KV, 2Ω IR, Wire-GND: ±6KV, 12Ω IR, (Criterion R)
EN61000-4-5
DIP The voltage derates to 70%Ut and the duration is 100ms (5 periods), conforms to criterion B at 0°,45°,90°,135°,180°,225°, 270°, 315°. EN61000-4-11
Ut=264Vac:Criterion A
Ut=220Vac:Criterion A
Ut=90Vac:Criterion A
The voltage derates to 70%Ut and the duration is 20ms(1 period),conforms to criterion B at 0°,45°,90°,135°,180°,225°, 270°,315°. EN61000-4-11(Criterion B)
The voltage derates to 0%Ut and the duration is 10ms(Half a period) EN61000-4-11(Criterion B)
Others EN61000-4-11(Criterion B)

2.7. Other requirements
Item Requirements Property
Acoustic noise <50dB(A) Pass
MTBF ≥80,000H  
Annual repair rate ≤0.2%  
Operation vibration 5-9Hz,3.5mm;9-200Hz: 1g; 3 axes, SF for 5 times per axis Pass
Random vibration Acceleration spectral density, 5~20Hz: 1.0;20~200Hz: -3dB; RMS acceleration: 0.781Grms
3 axes
Testing duration: 30min per axis
Pass
Impact Impact waveform: Half-sine wave;
Acceleration Vp: 300m/s2
Pulse width: 6ms;
6 axes
3 times per axis
Pass
Bump Bump waveform: Half-sine wave;
Acceleration Vp: 180m/s2
Pulse width: 6ms;
6 axes
100 times per axis
 
Drop Weight: ≤15kg
Height: 100cm
Drop test for 1 angle, 3 prisms and 6 surfaces:
Angle:
Choose the frailest one for test, if unavailable, the angel 2-3-5 shall be applied.
3 pcs of prisms: prism that joint at the base angle
6 pcs of faces: surfaces of tested unit
Drop time: once per surface
 
Damp proof 24~45ºC,95%RH,48h GB/T 2423.4-1993
Mildew proof Mildew test  Class B GB/T 2423.16-1999
Smog proof Smog test, 96H GB/T 2423.17-1999
Dustproof Dust with diameter more than 5um shall be not more than 3×104 particles/m3,the dust particles shall be non-conducting and non-corrosive. Pass
Static pressure TL=Wt×(S-1)×F×9.8(N)
TL: pressure applied, unit: N; Wt: weight of packaged piece, unit: kg;
S: stack available, adopt the maximum value;
F: safety coefficient, usually specified as 5;
S=3/h;
h--height of packaged piece, unit: m
The pressure shall be imposed for 2H.
 
Low voltage Tested at 4000m altitude Refer to GB2423