| Input | ||||||
| Item | Min | Typical | Max | Unit | Note | |
| DC Charger | Input Voltage | 100 | 300 | Vdc | ||
| Output Rated Voltage | 48 | Vdc | ||||
| Output Current | 30 | A | ||||
| AC Charger | Input Voltage | 90 | 220 | 280 | Vac | |
| Input Rated Voltage | 120 | Vac | ||||
| Input voltage frequency | 57 | 60 | 63 | Hz | ||
| Power Factor | 0.99 | |||||
| Output Voltage | 48 | Vdc | ||||
| Output Current | 50 | A | ||||
| Output | ||||||
| Item | Min | Typical | Max | Unit | Note | |
| AC(OUT) Inverter | Output voltage | 115 | 120 | 125 | Vac | |
| Output Rated Voltage | 120 | Vac | ||||
| Output Voltage Frequency | 57 | 60 | 63 | Hz | ||
| Output Current | 30 | A | ||||
| AC Bypass | Output Rated Voltage | 90 | 164 | Vac | AC first | |
| Output Voltage Frequency | 60 | |||||
| Output Current | 30 | A | ||||
| BAT+ BAT-(OUT) | Output Voltage | 48 | Vdc | BAT output directly, with protection of short and current limit | ||
| Output Current | 5 | A | ||||
| DC1+ DC2+ DC3+ GND(OUT) | Output Voltage | 300 | Vdc | There's equipped with output interface and the user can connect a certain load to absorb the excess power when the PV input exceeds the max DC charging | ||
| Protection | ||||||
| Item | Min | Typical | Max | Unit | Note | |
| Each Module | Over Temperature | Output is cut off when the inside temperature of heat sink is up to the peak point, then it will reduce 10ºC | ||||
| Output Over Current | Also protection of over power and short | |||||
| BMS | ||
| Battery Management | DC Charger | MPPT, charge with the max power |
| AC Charger | Constant current charge first, constant voltage charge later | |
| Over/under Voltage Protection | With BMS itself | |
| Insulation | |||||
| Item | Min | Typical | Max | Unit | Note |
| Input-Cabinet | 2121 | Vdc | Only test DC charge, AC charger and inverter | ||
| Input-Output | 2121 | Vdc | |||
| Output-Cabinet | 750 | Vdc | |||
| Isolated Resistance | All the isolated resistance of input-output, input-earth and output-earth is no less than 10MΩ under the situation of normal atmosphere, 90% humidity and 500Vdc test voltage. | ||||
| Environment | |||||
| Item | Min | Typical | Max | Unit | Note |
| Working Temperature | -10 | 40 | °C | ||
| Extended Working Temperature | -20 | 50 | °C | ||
| Storage Temperature | -10 | 60 | °C | ||
| Humidity | 90 | % | |||
| Atmosphere | 70 | 106 | KPa | ||
| Altitude | 0 | 3000 | m | ||
| Cooling | Fan | ||||
| Dust Proof | Requirement of dust: diameter: >5um, density: ≤3×104pcs/m3, non-conductive, non-magnetic and non-caustic. No protection of water proof | ||||