Certification:
Item |
Certification No. |
UL |
E255641 |
CCC |
2008010907293744 |
TABLE OF CONTENTS
1INTRODUCTION. 4
2 SPECIFICATION REQUIREMENTS. 4
2.1 Environmental Requirements
4
2.2 Input Properties
4
2.3 Output Electric Properties
4
2.4 Protection
5
2.5 SAFTY AND INSULATION
. 5
2.6 EMC
. 6
2.7 Other specifications
6
3 MECHANICAL SPECIFICATIONS. 7
3.1 Diagram
. 7
3.2 Installing dimensions
7
3.3 Output connector assignments
7
3.4 Labels and package
7
4 SAFTY 8
4.1 Unpacking
8
4.2 General rules
8
4.3 Notes concerning damaged security protection
8
4.4 Notices
8
5 Package, Transport, Storage. 8
5.1. Package
8
5.2. Transport
8
5.3. Storage
9
6 Scope of Warranty. 9
6.1. Time Limit of Warranty
9
6.2. Scope of Warranty
9
6.3. Operational Safety Guidance
9
7 Cited standards. 9
1INTRODUCTION
GPAD301M24-3B is a AC/DC middle-duty power supply with multi-output. Due to the latest circuit design, it is compact and of reliable performance. It has the wide range of input voltage and has many functions including the functions of short-circuit, over-current, over-voltage and over-heating. The cooling way is by fan. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technological equipment.
2 SPECIFICATION REQUIREMENTS
-
-
-
-
-
- Environmental Requirements
2.1.1 Operating temperature: -25ºC~+55ºC
2.1.2 Storage temperature: -45ºC~+85ºC
2.1.3 Relative humidity: 10%~95%
2.1.4 Absolute altitude: ≤3000m
2.1.5 Atmospheric pressure: 70~106KPa
2.1.6 Cooling: Cooling by fan
-
-
-
-
-
- Input Properties
Item |
Unit |
Min |
Typical |
Max |
Testing Conditions |
Input voltage range |
Vac |
88 |
110 |
132 |
Manual Switching |
176 |
220 |
264 |
Range of input voltage frequency |
Hz |
47 |
50 |
63 |
|
-
-
-
-
-
- Output Electric Properties
2.3.1 Basic output requirements
Output voltage |
Output current range |
Regulation |
Load regulation |
Line regulation |
Ripple +Noise |
+5V |
0.3A~6A |
≤±3% |
≤±3% |
≤±3% |
≤150mV |
+12V |
0A~5A |
≤±3% |
≤±3% |
≤±3% |
≤200mV |
+24V |
0.2A~6.5A |
≤±3% |
≤±3% |
≤±3% |
≤250mV |
Notes: (1) Measured with the rated voltage input and load, with 0.1UF filmy capacitor and 10UF/50V high frequency electrolytic capacitor at the output, oscilloscope bandwidth of 20MHz.
(2) Start up at 5V with no load and with 11A can be powered by 24V alone.
2.3.2 Other requirements
Item |
Unit |
Min |
Typical |
Max |
Testing Conditions |
Output Power |
W |
80 |
250 |
|
Rated input/output |
Output Efficiency |
% |
80 |
|
- |
Rated input/output |
Temperature coefficient |
/ºC |
|
|
±0.02% |
|
Output start up time |
S |
|
|
2 |
|
-
-
-
-
-
- Protection
Item |
Unit |
Yes/No |
Min |
Typical |
Max |
Recovery characteristics |
+12V output over-voltage protection |
V |
Yes |
13.2 |
|
14.6 |
Automatic recovery |
+24V output over-voltage protection |
V |
Yes |
27 |
|
30 |
Automatic recovery |
+5V output current limiting protection |
A |
Yes |
20 |
|
25 |
Automatic recovery, other output with no load. |
+12V short-circuit protection |
|
Yes |
Long-term short circuit endurable, automatic recovery |
-
-
-
-
-
- SAFTY AND INSULATION
Item |
Level |
Standards(or testing conditions) |
Insulation voltage ( output to ground) |
500Vdc |
500Vdc /1 Min / Leakage Current≤10mA |
Insulation voltage ( input to ground) |
1500Vac |
1500Vac /1 Min / Leakage Current≤10mA |
Insulation voltage ( input to output) |
1500Vac |
1500Vac /1 Min / Leakage Current≤10mA |
Insulation resistance |
10MΩ |
Under normal atmospheric pressure, and when the relative humidity is 90%, and the testing voltage is DC 500v, for the power supply, the insulation resistance of input to output, input to ground, and output to ground is not less than10M. |
Grounding resistance |
≤0.1Ω |
|
Leakage current |
≤3.5mA |
220Vac |
-
-
-
-
-
- EMC
Item |
Requirements |
Standards |
CE |
CLASS B |
EN55022 |
RE |
CLASS B |
EN55022 |
ESD |
There is no influence to power supply during discharge to the case after power supply is encased. Contact discharge: ±4KV |
EN61000-4-2(Criterion B) |
EFT/B |
Criterion B: 1KV |
IEC61000-4-4 |
SURGE |
Class B: Line-Line 2KV Line-Ground 2KV |
EN61000-4-5 |
-
-
-
-
-
- Other specifications
Item |
Requirements |
Performance |
Noise |
No screech |
Pass |
MTBF |
100,000H |
Pass |
Vibration |
>Frequency: 5 to 9 Hz
>Amplitude: 3.5mm,9~200Hz
>Direction: 3 axes
>Sweep frequency: 5 times(50minute per axis) > Acceleration:10m/s2, > Damage free to the power supply |
Pass |
Shock |
Half-sine wave, acceleration: 20G, Amplitude 11ms, Direction: 3 axes (X, Y, Z)
3 times per axis |
Pass |
Dustproof |
Dustproof to some extent |
Pass |
Odor |
No peculiar smell and deleterious gas |
Pass |
3 MECHANICAL SPECIFICATIONS
-
-
-
-
-
- Diagram
Overall dimensions: L(165mm)*W(173mm)*H(87mm)
-
-
-
-
-
- Installing dimensions
3.3 Output connector assignments
3PIN connector assignment (From up to down): Pin1-L wire, Pin 2-PGND, and Pin 3-N wire
6PIN connector assignment: Pin 1-5V, Pin 2-GND, Pin 3-Empty, Pin 4-24V Pin 5-GND, and Pin 6-12V
-
-
-
-
-
- Labels and package
4 SAFTY
-
-
-
-
-
- Unpacking
Check the equipment, and make sure they are not damaged in transport. Keep the package until all of the modular units in the power equipment are registered and checked.
-
-
-
-
-
- General rules
The air passage of the modular unit should not be blocked.
The distance between the conductive part and metal component in the power equipment should conform to the relevant standards.
-
-
-
-
-
- Notes concerning damaged security protection
Once the security protection of the equipment is damaged, the equipment must stop operation and handled according to the relevant maintenance regulations.
When the power equipment is moved from a cold environment to a warm environment, condensation may lead to hazard issues, so the equipment should be grounded strictly according to the grounding requirements. Only qualified personnel can connect the equipment to the electrical supply.
After power cut off, wait four minutes to allow sufficient capacitor discharge before maintenance of the power equipment.
-
-
-
-
-
- Notices
To operate under the environmental conditions in the Specification;
Forbid to adjust potentiometer without authority;
Switching power supply should be in the good cooling conditions -operating; it should be shut off if there is smoke or odor at turn on or operation.
5 Package, Transport, Storage
-
-
-
-
-
- Package
On the packing box, there are product name, model, manufacturer logo, quality certificate, and date of production, etc. In the packing box, there are specification and accessory list.
-
-
-
-
-
- Transport
This product is suitable for land, water, and air transport. In the transport, the product should be covered, protected against direct sunlight, and handled with care.
-
-
-
-
-
- Storage
When the product is not in use, it should be placed in the packing box in an warehouse with an ambient temperature of -40~+85ºC and relative humidity of 10%~90%. The warehouse should be free of harmful gas, inflammable, explosive or corrosive items, and should also be free of intense mechanical vibration, impact and intense magnetic field. The packing box should be padded at least 20cm high above the ground, and at least 50cm away from the wall, heat source, or window-type air inlet. Under the above storage conditions, the storage duration is 2 years. After that, the product should be tested again.
6 Scope of Warranty
-
-
-
-
-
- Time Limit of Warranty
In 1 year warranty, we provide free maintenance for all natural damages under normal operation conditions, except
Damages resulting from unauthorized maintenance;
Unauthorized addition or modification;
Incorrect operations and use;
Damages resulting from exposure to the abnormal ambient conditions that are not stipulated in the specifications;
Deliberate destruction on the system; and
Force majeure damages.
-
-
-
-
-
- Scope of Warranty
In time limit of warranty, our Company can maintenance for free for the abnormal caused by the fault of materials and manufacture technique. The scope of warranty include labor server and any necessary adjustment and replace of components
-
-
-
-
-
- Operational Safety Guidance
Please be sure to observe the following rules of security stipulated at any time, such as operation, cleaning and maintains. If there is any deregulation beyond the rules, our Company is with responsibility for mistakes caused by deregulations.
- Forbid operate in conditions with volatility gas and flammability.
- Forbid uninstall case and touch inside components at any time
- For the sake of safety, forbid do inside maintenance and replace components by self.
7 Cited standards
Standard Ad, GB2423.1 - 89 Basic Test Procedures for Electrical and Electronic Products.
Test Bd, GB2423.2 - 89 Basic Test Procedures for Electrical and Electronic Products.
Test Cb, GB2423.9 - 89 Basic Test Procedures for Electrical and Electronic Products.
Standard FC, GB2423.10 - 95 Basic Test Procedures for Electrical and Electronic Products.
GB/T13722. - 92 Specifications and Testing Methods for Mobile Communication Power Supply.
ST2811.2 - 87 Testing Methods for General DC Stabilization Power Supply.
GB4943. - 1995 Security of IT Facilities, Including Electrical Equipment.
ETS300019 - 1 - 1 Memory.
ETS300019 - 1 - 2 Transport.
GB3873 - 83 General Specifications for Communication Equipment Package.
Detailed Quality Certification and Testing Regulations for Network Access of Communication-Purpose Co-frequency Switching Power Supply.
YD/T731 - 94 Communication-Purpose H.F. Switching Rectifier.
XT-005-95 General Specifications of Power Supply System for Communication Bureau/Station (Interim Regulations).