Model | Input voltage range (VAC) | Output voltage range (VDC) | Output current range (A) | Rated output power (W) | Overall dimension (L * w * h) |
GPAD201M4-1K | 90-264 | 3.3~4.0 | 0-40 | 160 | 165*46*26mm |
GPAD201M5-1K | 90-264 | 4.2~5.0 | 0-40 | 200 | 165*46*26mm |
GPAD201M6-1K | 90-264 | 5.5~6 | 0-33 | 198 | 165*46*26mm |
2. 1 input characteristics | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
working temperature | -30 | 70 | °C | ||
Storage ambient temperature | -40 | 85 | °C | ||
Working relative humidity | 20 | 95 | % | No condensation | |
Storage relative humidity | 5 | 95 | % | No condensation | |
Altitude | 5000 | m | High temperature derating at 3000-4000m operating environment, 1 ºC for every 200m increase | ||
atmospheric pressure | 70 | 106 | KPa | ||
Heat dissipation mode | Natural conduction and heat dissipation | ||||
Input voltage range | 90 | 220 | 264 | Vac | |
Input current | 3 | A | |||
Input impulse current | 50 | A | 220VAC input, output full load | ||
Input frequency | 47 | 50 | 63 | Hz | Full range normal operation |
power factor | 0.95 | 220VAC input, output full load | |||
Harmonic distortion | 15 | % | 230VAC input, output half load or full load |
2.2 output characteristic | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
output voltage | 3.3 | +4.6V | 6.0 | Vdc | Output voltage is set according to factory requirements |
Output current range | 0 | 40 | A | ||
output power | 200 | W | |||
Output efficiency | 91 | % | 220VAC input, full load output | ||
Ripple (peak to peak) | 200 | m Vp-p | At the rated input / output, add one 0.1 μ f ceramic chip capacitor and one 10 μ f high frequency electrolytic capacitor, and measure the bandwidth at 20MHz. | ||
Load adjustment rate | ±2 | % | |||
Source adjustment rate | ±0.5 | % | |||
temperature coefficient | ±0.03 | %/ºC | |||
Switching machine overshoot | ±10 | % | |||
Dynamic response overshoot | ±5 | % | 25% - 50% - 25% or 50% - 75% - 50% load change, load mutation rate is 0.1a/μ s, calculated as the part beyond the output voltage stabilization accuracy range | ||
Dynamic response recovery time | 200 | ūS | |||
Power on output delay | 2 | S | Input 220VAC, output full load |