Main specifications of the products | |||||
Input voltage range (Vdc) | Output Voltage (Vdc) | Output current (A) |
Output voltage adjustable range (%) | Output Ripple and Noise (mVp-p) |
Typical efficiency at full load (%) |
9~40 | 24.0 | 0~6.25 | -20~+10 | 150 | 90.0 |
Input characteristics |
Input Operating Voltage Range | 9 | 12 | Vdc | ||||
12 | 24 | 40 | Vdc | ||||
Maximum input current | 45 | Vdc | |||||
No-load input current | 50 | Vdc | |||||
Standby input current | 15 | A | |||||
Input transient inrush current | 300 | mA | |||||
Input reflected ripple current | 20 | 30 | mA | ||||
Input Operating Voltage Range | 1 | A2s | |||||
Maximum input current | 500 | mA | |||||
Input Operating Voltage Range | 1 | mA | |||||
Positive logic | Remote control activation level | 2.4 | 18 | Vdc | |||
Remote control shutdown level | 0 | 0.8 | |||||
Negative Logic | Remote control activation level | 0 | 0.8 | Vdc | |||
Remote control shutdown level | 2.4 | 18 | |||||
Input Undervoltage Voltage protection |
Overvoltage protection threshold | 6.5 | 7.5 | 8.5 | Vdc | ||
Overvoltage recovery threshold | 7.0 | 8.0 | 9.0 | Vdc | |||
Overvoltage protection hysteresis | 0.5 | Vdc | |||||
Input external capacitor | 330 | µF | |||||
Output characteristics | |||||||
Output voltage accuracy | ±1. 5 | %Vo | |||||
Range of output voltage calibration value | 23.88 | 24.00 | 24.12 | Vdc | |||
Output voltage adjustable range | -20 | +10 | %Vo | ||||
Voltage Adjustment Rate | ±0.5 | %Vo | |||||
Load Adjustment Rate | ±1.0 | %Vo | |||||
Power | 100% load | 88.5 | 90.0 | % | |||
Output current | 0 | 6.25 | A | ||||
Output overcurrent protection | 7.0 | 12.5 | A | ||||
Short Circuit Protection | |||||||
Output Overvoltage Protection | 27.5 | 28.5 | 29.5 | V | |||
Output Ripple and Noise | 150 | mVp-p | |||||
Output external capacitor | 660 | 3000 | µF | ||||
Input power-on delay time | 5 | 15 | ms | ||||
CNT startup delay time | 5 | 15 | ms | ||||
Output voltage rise time | 10 | 25 | ms | ||||
Switching output voltage overshoot amplitude | ±5 | %Vo | |||||
Remote switch-on overshoot amplitude | ±5 | %Vo | |||||
Transient Response | Overshoot amplitude | ±5 | %Vo | ||||
Recovery time | 400 | 900 | µs |