Customization: | Available |
---|---|
Usage: | Light, Industry, Construction |
Output Type: | Single |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ambient Requirements | |||||
parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temperature | -25 | 65 | 85 | °C | |
Storage temperature | -25 | 25 | 100 | °C | |
Relative humidity | 5 | 95 | % | No condensing | |
Altitude | 0 | 4000 | m | Max temperature will be derated by 1ºC per200m @ altitude of 3000~4000m | |
Cooling | Conductive cooling |
Input | |||||
parameter | Min. | Typ. | Max. | Unit | Remark |
AC input voltage range | 90 | 110/220 | 264 | Vac | |
AC intput voltage frequency | 47 | 50/60 | 63 | Hz | |
Power factor | 0.95 | 220Vac full-load | |||
Inrush current | 50 | A | 220Vac full-load/ cold state | ||
AC input phase | Single-phase input L,N |
Support for single-phase |
Output | |||||
parameter | Min. | Typ. | Max. | Unit | Remark |
Output voltage range | 3.8 | 4.2 | 4.6 | Vdc | adjustable |
Output setting voltage | 4.15 | 4.2 | 4.25 | Vdc | |
Output current range | 0 | 80 | A | All-voltage input range | |
Regulation | ±1 | % | Rated voltage input,variation:all-loads | ||
Stabilized voltage precision | ±5 | % | All-voltage input range/all-load output | ||
Load regulation | ±0.5 | % | Rated current output; Variation:all-voltage range |
||
Ripple +noise(Vp-p) | 200 | mV | all input voltage and load range, with a 0.1uF film capacitor and 10uF electrolyte capacitor,oscilloscope band width of |
Other outputs | |||||
parameter | Min. | Typ. | Max. | Unit | Remark |
Outpu power | 370 | W | |||
Output efficiency | 86 | 90 | % | 220Vac input,output all-load,@normal temperature | |
Dynamic response overshoot | ±5 | % | Load variation:25%-50%-25% or 50%-75%-50% Rate: 0.1A/us,cycle:4ms |
||
Dynamic response overshoot | ±10 | % | |||
Temperature coefficient | ±0.02 | %/ºC | Rated output voltage and output current,all operating temperature range | ||
Startup output delay | 2 | S | 220Vac ,full-load | ||
Startup/turndown overshoot | ±10 | % | All-voltage input range,all-load ouput | ||
Output voltage rise-up time | 200 | ms | Rated input/outpu | ||
Capactive load | 4700 | 10000 | uF | All voltage,load range |
Protection | |||||
parameter | Min. | Typ. | Max. | Unit | Remark |
Output over-voltage protection point | 5.5 | 6 | V | Output be dead-locked | |
Output current-limiting protection point | 90 | 110 | A | ||
Output short-circuit protection | Long-term short-circuit endurable; auto-recoverable |
||||
Over-temperature protection | 90 | 100 | ºC | Turn off @ over-temperature, auto-recoverable. Tested @ the central of the enclosure |