Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview | |||||
Model |
Input voltage |
Output voltage |
Output current |
Rated power |
Dimensions (L*W*H) |
GPAD202M60-2A | 180~265 Vac | 60 Vdc | 33.5 A | 2000 W | 380*145*48mm |
GPAD202M125-2A | 180~265 Vac | 125 Vdc | 16 A | 2000 W | 380*145*48mm |
GPAD352M60-2A |
180~265 Vac |
60 Vdc |
58.5 A |
3500 W |
380*145*48mm |
GPAD352M125-2A | 180~265 Vac | 125 Vdc | 28 A | 3500 W | 380*145*48mm |
Input Characteristics | |||||
Parameters | Min | Typical | Max | Unit | Annotation |
Input voltage range | 180 | 220 | 265 | Vac | Single-phase three-wire: L+N+PE |
Grounding Method | The power supply protection ground is connected separately to the enclosure | ||||
Input frequency | 47 | 50/60 | 63 | Hz | At rated load |
Power factor (PF) | 0.99 | / | At rated input and rated power output | ||
Input current | 25 | A | |||
Inrush current | 40 | A | |||
DC Startup time | 3 | S | From 220Vac input, ON/OFF signal to stable DC output | ||
Overall Startup Time | 8 | S | From ON/OFF signal, 220Vac input to stable DC output | ||
Input Protection Features | |||||
Over-voltage protection | 280 | 320 | Vac | Half-load test, Auto-recovery | |
Over-voltage recovery | 270 | 300 | Vac | ||
Under-voltage protection | 150 | 175 | Vac | Half-load test, Auto-recovery | |
Under-voltage recovery | 160 | 180 | Vac |
Output Characteristics | |||||
Parameters | Min | Typical | Max | Unit | Annotation |
Output voltage range |
122 |
125 |
127 |
Vdc |
Adjustable via potentiometer Default voltage: 125V Adjustment accuracy: ≤±0.2V. |
No-load output voltage | 125 | Vdc | |||
Rated output current | 0 | 16 | A | 2000W output power | |
Voltage regulation accuracy | ±1 | % | Full voltage range, full load range variation | ||
Source regulation | ±1 | % | Rated current output, full voltage range variable | ||
Load regulation | ±1 | % | Rated voltage input, full load range variation | ||
Temperature coefficient | ±0.02 | %/°C | Rated voltage, current output; full operating temperature | ||
Dynamic response recovery time | 500 | uS | 25%~50%~25% load change, Hop rate: 1A/us, Hop cycle: 4ms | ||
Dynamic response overshoot | ±5 | % | |||
Noise and ripple (peak-to-peak) | 400 | mV | *Note 1 | ||
Switching on/off overshoot | ±5 | % | |||
Output efficiency | 93 | % | Rated input, rated load | ||
Output Voltage Rise Time | 240 | mS | Rated input, full load, the output voltage rises from 10% to 90% | ||
Main Circuit Shutdown Delay |
800 |
mS |
After receives the shutdown signal from the control interface SW, it should stop operating within 800 ms |
||
Main Circuit Dynamic Characteristics |
The instantaneous drop or overshoot of the output voltage should not exceed ±5%, and it should not cause abnormal operation or protection of the power supply |
Load Change |
Loading: The output changes from 0 to full load within 10 μs. Unloading: The output changes from full load to 0 within 10 μs. Full voltage range input, Modulation frequency from 5Hz to 5KHz; Duty cycle from 20% to 100%; Output power settings at 50%, 80%, and 100%; These conditions are combined in various ways to test the output under each setting. |
||
The output pulse waveform should have no significant distortion or damping, and there should be no abnormal operation or protection triggered in the power supply |
Pulse Modulation |
ON/OFF control | Low Level: Power supply starts (connected to GND) High Level or Floating: Power supply shuts down |
||
Capacitive Load | ≤1000 | uF |