Basic Info.

Model NO.
PPC12 A020B
Output Power
101 - 200W
Input Voltage
90-286VAC / 130-400VDC
Certification
CE, RoHS, CCC, CB, FCC
Brand
Goldpower
Transport Package
Carton
Trademark
Goldpower
Origin
China
HS Code
8504401400

Product Description

Welcome to use PPC12A020B customized power supply from Shenzhen Gold Power.The power supply normally works with 90~286Vac or 130~400Vdc,and 12V oneway output. The power supply is equiped with protections against input over-current,input over/under-voltage and input reverse connection prevention.Remote signal function is also provided.The power supply is designed strictly in accordance with the safety regulations,which conforms to the safety standards and requirements of information technological equipment.
1.Specification
Environmental requirements
Parameter Min. Typ. Max. Unit Remark
Operating temperature -30 25 65 ºC  
Nominal operating temperature -25 25 55 ºC Safety rule certificated range
Relative humidity 5   95 % Long-term operation,no condensing
Altitude 0   5000 m Max operating temperature will be derated by 1ºC per 200m @ altitude obove 3000m.
Cooling Forced cooling by fan.
Working time Continuously work for 24 hrs everyday.
           
Remark :The location of power supply in outdoor cabinet is as below
 (power supply in the figure is an example)
Power suppply
Storage requirements
Parameter Min. Typ. Max. Unit Remark
Storage temperature -40 25 85 ºC  
Relative humidity 5   95 %  
Altitude 0   5000 m  
Max temperature variation rate     3 ºC/min  
 
AC input
Parameter Min. Typ. Max. Unit Remark
Nominal input voltage 100 110/220 240 Vac Nameplate nominal voltage,within which safety rule certificated.
Input operating voltage range 90 110/220 286 Vac Regular work
130 240 400 Vdc Regular work,no certification requirement.
Remark 1
Max input voltage     315 Vac Inoperation under this voltage is allowed,
but no damage with the power supply
AC input frequency 45 50/60 66 Hz  
Power factor   0.95     Normal temperature rated input/output
Input inrush current       A Test @ normal temperature,
rated input/output,cold start.
Meet the standard of ETSI300132,
Remark2
Input current     2.8 A Test @ nominal min. input voltage,rated/max output current
Input reverse connection prevention The power supply can work properly @ reverse connection,with fuses @ L,N
Grounding AC PE on the front panel connects with the enclosure of power supply,which connecting with system grounding through the grounding screw.
           


Remark 1:EMC test @ rated input 110 Vac and 220 Vac,rated output voltage,system max configuration load current
Remark 2:ETSI300132 requirement for input inrush current













 
Output   (figure 1)
Parameter Min. Typ. Max. Unit Remark
Rated output voltage   12   Vdc Test @ the connection part of output terminal and PCB.
Output voltage setting value 11.6 12 12.4 Vdc Rated input voltage,output half-load.
Test @ output terminal.
Output current     15 A Full-power output @ fan >1.5m/s;
Output >=130W when 1.0m/s <= fan speed<1.5m/s .
Output rated power     180 W
Output voltage range 11.6   12.4 Vdc All input/output load
Ripple (Vp-p)     120 mV 20MHz bandwidth,
Test with a 0.1uF electrolytic capacitor
and 10uF capacitor
efficiency 220V 83     % Normal temperature,220Vac input, 25% load
87     Normal temperature,220Vac input, loads more than 50%(50%,75% and 100%)
110V 81     Normal temperature,110Vac input, 25% load
85     Normal temperature,110Vac input, loads more than 50%(50%,75% and 100%)
240V 85     Normal temperature,240Vdc input, loads more than 50%(50%,75% and 100%)
Transient response recovery time     200 us Load variation:25%~50%~25%or 50%~75%~50%,rate:0.1A/uS.
Transient response overshoot -5   +5 %
Startup output delay     4 s Rated input/output
Startup/shutdown overshoot -5   +5 %  
Output voltage rise-up time 1   50 ms Startup @ rated input & full-load output, the duration for 12V output voltage rising from 10% to 90% in monotonically increasing wave.
Capacitive load 4000     uF Common aluminum electrolytic capacitor
Temperature coefficient -0.02   +0.02 %/ºC The difference between DC output voltage and DC output setting voltage should be no more than the DC output setting voltage ± 0.02%.
Delay @ power failure 5     mS Test @ 220VAC rated(220Vac±20%)
full-load,please refer to the remote signal function description for details.
Output common GND 12VGND and PE independent.
             
 
Protections
Parameter Min. Typ. Max. Unit Remark
Input over-current protection With input over-current protection function.Fusing @ over-current,but components of the power supply shall not be damaged.
Enable double livewires input,fuse protection shall be set @ L and N.
Input over-voltage protection 291     Vac  
Input over-voltage recovery point 286     Vac  
Input over-voltage protection hystersis 5     Vac  
Input under-voltage protection point     85 Vac The power supply shall not be damaged when input voltage is below min. operating voltage.
Input under-voltage recovery point     90 Vac
Input under-voltage protection hystersis 5     Vac
Output over-current protection 16.5   22.5 A Hiccup,auto recoverable after over-current be removed.
Output over-voltage protection 13.2   14.6 A Hiccup,auto recoverable after over-current be removed.
Transient over-voltage protection point<16.8V
Over-temperature protection The power supply shall not conduct protection and work properly within required temperture range ;The power supply shall automaticlly recover after recovering to normal temperature.
There shall be an alarm before over-temperature protection.
Output short-circuit protection Hiccup,auto recoverable after short-circuit be removed;the power supply shall not be damaged if long-term circuit.
Input reverse connection protection Fuse protection shall be set @ L and N.
           
 
EMC requirements
No. Item Requirement Standard
SR-PPC12 A020B-2100 (ESD) Air discharge:±8KV EN61000-4-2 (Criterion B)
Contact discharge:±6KV EN61000-4-2 (Criterion B)
SR-PPC12 A020B-2101 (RS) Test frequency:80MHz~800MHz,960MHz~1.4GHz,2.7G~ 6GHz,Electric field intensity:3V/m;
Test frequency :800MHz~960MHz,1.4G~2.7GHz,Electric field intensity:10V/m;
Amplitude modulation:80%AM(1kHz)
EN61000-4-3 (Criterion A)
SR-PPC12 A020B-2102 (CS) Test frequency:0.15 MHz~ 80 MHz,Test intensity:3V,Amplitude modulation:80%AM(1kHz) EN61000-4-6 (Criterion A)
SR-PPC12 A020B-2103 (EFT/B) ±2kV EN61000-4-4 (Criterion B)
SR-PPC12 A020B-2104 (SURGE) Basic test:(Remark 3)
Line-line:±2.5kV(internal resistance:2Ω);Line-ground:±2.5kV(internal resistance:2Ω)
Enhanced test:
Line-line:±6kV(interval resistance:2Ω);line-ground:±6kV(internal resitance:2Ω)
EN61000-4-5
Criterion B

 
SR-PPC12 A020B-2105 SURGE Input Line-line:±5kA;Line-ground:±5kA(Remark 3) Standalone machine test YD/T 5098-2001
8/20 μs waveform(Criterion C)
With the system:common mode 15KA/difference mode15KA(5 times for ±) Test with lightning arrester@ inpu,
lightning arrester code :
044070300010
Output With the system:Line-line:±5Ka;Line-ground:±5kA Test with 5KA  lightning arrester @ output,
residual voltage< 50V
SR-PPC12 A020B-2106 (DIP) Dip to 70%Ut,duration:500ms, criterion B;
Dip to 0%Ut,duration:10ms,20ms,criterion B;
Dip to 0%Ut,duration:5000ms,criterion C.
EN61000-4-11
Ut=220Vac
SR-PPC12 A020B-2107 (CE) CLASS A(Remark 1)  
SR-PPC12 A020B-2108 (RE) CLASS A(Remark 1)  
SR-PPC12 A020B-2109 Current harmonics Meet the requirement of CLASS A . IEC61000-3-4
SR-PPC12 A020B-2110 Voltage fluctuation Pst 1.0;P1t 0.65; dc3%; dmax4%;
Duration for d(t) >200mS is less than 3%
IEC61000-3-3
           

Remark1: EMC test shall be conduted @ rated input 110 Vac and 220 Vac,rated output voltage,system max. configuration load current.
Remark2:
Criterion A (for continuity):
a) DC output range shall be accordant to normal work situation during interference;
b) There shall not be alarms and failure indicated at tested unit during or after interference.
Criterion B (for transience):
a) DC output voltage shall not affect CriterionB during the test;
b) Spikes during interference shall not be considered.
c) There shall not be alarm and failure indicated at tested unit during or after interference.
d) Recover to normal function after interference.
Criterion C (for interruption):
The temporary lose of function is allowed, the function shall be recoverable automatically or manually, as well as by operation.
Criterion R (for susceptibility)
There shall not be damage or other interruption upon unit during test, eg, software damage or improper operation of protecting unit. The unit shall operate appropriately within specified range and not necessarily during process of test. The interference may result in actions of fuse or other device defined, and shall be replaced or reset before recovering to normal operation state. 
Remark 3: SPD installed in the power supply, which is with the functions of over-current/heat-tripping, or protection components such as fuse @ circuit.
Remark 4:standalone machine test with pure resistance full-load in the system cabient.Test result shall meet the margin requirements of our company, or meet margin requirement of 6db for test out of our company.
Remark 5: High voltage DC input EMC requirements:
Test voltage:rated input voltage 240 VDC;
Test items:all items(except for DIP and communication for the;
RE and CE Specification prolong 20 db, and satisfy the margin requirement of Remark 4.


 
Others
Items Requirement Remark
Odor No peculiar and deleterious odor  
Component The electric and temperature stress shall meet derating requirement specified by supplier,to ensure components reliability. Max operating temperature of electrolyte capacitor at input/ output side shall be 105ºC.  
Proofing requirement Proofing procedure shall be taken for PCBA of samples and lots.
Material :polyurethane;thickness: 25~50um.
 
ROHS ROHS5  
MTBF 500 thousand hours 25ºC,rated input,
full-load output
Lifetime 10 years 25ºC,rated input/output current
Salt fog prevetion Salt fog test, 96H Standalone machine test . GB/T2423.17.
Vibration 5-9Hz,Amplitude:1.2mm;9-200Hz:acceleration:0.4g;3 axes,5cycles per axe. Unpacked
Dip Height :0.10m,sides :S1,S2;corner:C1,C2,1time. Unpacked
Shock Frequency Acceleration Spectral Density:
1~4Hz:0.0001~0.01g2/Hz;
4~100Hz: 0.01g2/Hz;
100~200Hz:0. 01~0.001g2/Hz;
Root-mean -square acceleration:Grms=1.15g
Test axes:3.
Duration : 30min per axe.
Packed
bump Half sine-wave;peak acceleration:30g;pulse width:11ms;directions:6;times: 3times per direction. Packed
collision Half sine-wave;peak acceleration:18g;pulse width:6ms;directions:6; times: 100 times per direction. Packed
Drop Weight     Height   
15kg,   100cm
Drop at 1 angle,3 edges and 6 surfaces:
1angle:The weakest angle shall be selected for drop test,otherwise,angle2-3-5 3 edges:edges intersect at obove angle
6 surfaces:external surfaces of package unit
times:1 time per surface
Packed
 
Safety & insulation rating
parameter Standard Remark
Insulation voltage Input-output:3000Vac(or equivalent 4242Vdc)/10mA/60S No flashover or breakdown;
The discharge tube shall be removed during the test.
Input-ground:1500Vac(or equivalent 2121Vdc)/10mA/60S
Output -ground: 500Vac(or equivalent 707Vdc)/10mA/60S
Insulation resistance 2MΩ @ normal atmospheric pressure, relative humidity: 90% 
Testing voltage: 500V 
The insulation resistance of AC/DC-ground, AC-DC shall not be less than 2MΩ
Contact current(grounding) <3.5mA Input max. nominal operating voltage* 1.1
Contact current(output) <0.25mA
Ground impedance <0.1Ω Apply to AC input power supply with metal grounding enclosure