AC Input | |||||
Parameter | Min. | Typ | Max. | Unit | Remarks |
Input Voltage Range | 90 | 220 | 280 | Vac | |
Input Frequency | 45 | 50 | 65 | Hz | Rated load |
Input Current | 8 | A | |||
Power Factor | 0.99 | Rated input/rated load |
Output | |||||
Parameter | Min. | Typ. | Max. | Unit | Remarks |
Output Voltage Range | 21 | 27.5 | 28.5 | Vdc | |
Output Current Range | 0 | 40 | A | 176~280Vac Input | |
Voltage Regulation | ±1 | % | |||
Phone psophometric Weighting Noise | 2 | mV | |||
Wide Frequency Noise Voltage | 100 30 |
mV | (3.4KHz~150KHz) (150KHz~30MHz) |
||
Ripple (Vp-p) | 200 | mV | Rated input/output, with 0.1uF film capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz | ||
Output Power | 0 | 1100 | W | 176-280VAC input | |
0 | 550 | W | 90-175VAC input | ||
Output Efficiency | 90 | % | Output maximum efficiency | ||
83 | % | 110VAC input, half load |
Ambient requirements | |||||
Parameters | Min | Typ. | Max | Unit | Remark |
Operating temp | -40 | 55 | °C | @ 55ºC, operates normally with full load, +55~+65ºC auto derating , see remark 2 |
|
Extended operating temp | 55 | 65 | °C | Auto derating | |
Storage temperature | -50 | 80 | °C | ||
Humidity | 5 | 95 | % | Relative humidity, no condensing | |
Altitude | -60 | 4000 | m | For operation above 2500m (5000 ft.), Maximum operation temperature is derated by 2°C per 305m (1000 ft.). |
|
-200 | 13000 | ft | |||
Earthquake rating | 4 | Zone | |||
Audible noise | 50 | dB | Noise is proportional to fan speed, load and ambient temperature. | ||
Testing and working temperature should meet the following three requirements: (1) Start up with rated power 1100W during high voltage range (176-280VAC); (2) @55ºC~65ºC, auto derating of power is recommended. @65ºC, at least 50% rated power long time output with regulated voltage (3) @55ºC, maximum power output without over-temperature protection. The components shall work normally and meet the stress requirements |