Customization: | Available |
---|---|
Output Type: | Dual |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 20/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Operation environment | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operation temperature range | -40 | 25 | 80 | ºC | |
Nominal operation temperature range | -40 | 25 | 70 | ºC | Within safety certification range. |
Relative humidity | 5 | 95 | % | Long-term operation without condensing. | |
Altitude | 0 | 5000 | m | For operation above 3000m, the max. operation environment temperature is derated by 1ºC per 100m. | |
Working hours | 24 hours everyday. | ||||
Cooling | Nature cooling. Components with heating power more than 0.5 W shall be installed closely to the internal case for cooling. | ||||
Storage environment requirement | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Storage temperature range | -50 | 25 | 85 | ºC | |
Relative humidity | 5 | 95 | % | ||
Altitude | 5000 | m | |||
Max. rate of temperature variation | 5 | ºC/min |
Input | ||||||||||
Parameter | Min. | Typ. | Max. | Unit | Remark | |||||
Nominal input voltage range | 100 | 110/220 | 240 | Vac | Safety Certified in the range of Nameplate nominal voltage range. | |||||
Input operation voltage range | 90 | 110/220 | 286 | Vac | ||||||
130 | 200/300 | 380 | Vdc | |||||||
Max. input voltage | 315 | Vac | Under this input voltage, inoperation without damage is allowed,. | |||||||
Rated input voltage | 110/220 | Vac | ||||||||
AC input frequency | 45 | 50/60 | 66 | Hz | ||||||
Power factor | 0.95 | Test with rated input & typical load . | ||||||||
Input inrush current | A | Normal temperature, test with rated input & typical load output, cold-start. Comply with ETSI300132-3 Standard. |
||||||||
Double L wire input | There shall be fuse with L/N, inverse-prevention function is functional at high voltage DC input, the power supply can work normally without distinguishing for positive and negative polarity. | |||||||||
Grounding | +30V,+5.6V outputs sharing the same grounding. | |||||||||
Output | ||||||||||
Parameter | Min. | Typ. | Max. | Unit | Remark | |||||
Rated output voltage | Output 1 | 30 | Vdc | |||||||
Output 2 | 5.6 | |||||||||
Output voltage adjustable range | +30V | 20 | 31.5 | Vdc | ||||||
+5.6V | ||||||||||
Output voltage range | +30V | 29.1 | 30 | 30.9 | V | |||||
+5.6V | 5.48 | 5.6 | 5.72 | |||||||
Output current range | +30V | 0 | 12 | 15 | A | |||||
+5.6V | 5 | 8 | 10 | |||||||
Vp-p noise voltage | +30V | 200 | mV | 20MHz bandwidth limitation, with10uF/50V,0.1uF/50V capacitors. |
||||||
+5.6V | 100 | |||||||||
Output voltage setting value | -53.5 | -54 | -54.5 | V | Rated input,Rated output | |||||
Rated output current | 0 | 15 | A | 90≤Vin≤154 derating to 10A | ||||||
Output rated power | 810 | W | 90≤Vin≤154 derating to 540W | |||||||
Load regulation | ±3 | % | ||||||||
Voltage regulation | ±2 | % | ||||||||
Stabilized voltage precision | ±5 | % | ||||||||
Overall efficiency | 91 | 91.5 | % | Rated 220V input, typical load output, with environment temperature 25ºC. | ||||||
87 | Rated 110V input, typical load output, with environment temperature 25ºC. | |||||||||
Temperature coefficient | ±0.02 | %/ºC | ||||||||
Output power | 404.8 | 506 | W | |||||||
Dynamic response recovery time | +30V | 200 | µS | Load variation: 25%~50%~25% or 50%~75%~50%, Load changing rate is 0.1A/uS |
||||||
+5.6V | 200 | |||||||||
Dynamic response overshoot | +30V | ±5 | % | Load variation: 25%~50%~25% or 50%~75%~50%, Load changing rate is 0.1A/uS |
||||||
±10 | Large dynamic test, referring to Remark 1. | |||||||||
+5.6V | ±5 | Load variation: 25%~50%~25% or 50%~75%~50%, Load changing rate is 0.1A/uS |
||||||||
Startup output delay | 4 | S | ||||||||
Startup/shutdown overshoot | ±5 | % | ||||||||
Output voltage rise time | +30V | 1 | 200 | mS | ||||||
+5.6V | 1 | 20 | ||||||||
Capacitive load | +30V | 1500 | uF/A | The output voltage rise from 10% to 90%, rated load with the output waveform rising monotonically | ||||||
+5.6V | 4000 | |||||||||
Powerdown delay function | Related to DIP function. | |||||||||
Output ground-sharing | Two outputs sharing the same grounding. | |||||||||
Remark :Test with 154V≤Vin≤290V,output rated 54V/15A,and 90V≤Vin≤154V,output rated 54V/10A. | ||||||||||
Protection | ||||||
Parameter | Min. | Typ. | Max. | Unit | Remark | |
Input over-voltage protection point | 300 | V | Auto recoverable. There shall be no protection within 400Vdc at high DC input. Test with typical testing conditions. |
|||
Input over-voltage recovery point | 286 | V | ||||
Input over-voltage protection hystersis | 3 | V | ||||
Input under-voltage protection point | 87 | V | Auto recoverable. There shall be no protection for over 130Vdc at high DC input. |
|||
Input under-voltage recovery point | 90 | V | ||||
Input under-voltage protection hystersis | 3 | |||||
Output over-voltage protection | +30V | 35 | 45 | V | ||
+5.6V | ||||||
Output over-circuit protection | +30V | 16 | 30 | A | ||
+5.6V | 11 | 30 | ||||
Short-circuit protection | A | Long term short-circuit endurable. There shall be no damage. Auto recoverable after short-circuit be removed. |
||||
Over-temperature protection | ºC | The power supply is equiped with over-temperature protection function and no damage @ protection. Auto recoverable when temperature fall to environment temperature range.The power supply can operate properly in the range of specified temperature without over-temperature protection.Over-temperature protection hystersis is more than3ºC.The temperature of components will not exceed the max. operation temperature before protection. | ||||
EMC Specification Requirement | ||
Item | Specification requirement | Standard |
ESD | Air discharge: ±4KV, ±15KV Contact discharge: ±8KV |
EN61000-4-2 (Criterion A) |
RS | Testing range:80M~6G; Testing intensity: 800MHz~960M: 10V/M 1.4GHz~2.7GHz: 10V/M Others range: 3V/m Amplitude modulation: 80%AM(1kHz) |
EN61000-4-3 (Criterion A) |
CS | Testing frequency: 0.15 MH~80 MHz, Testing intensity: 10V, Amplitude modulation: 80%AM(1kHz) |
EN61000-4-6 (Criterion A) |
EFT/B | ±4KV | EN61000-4-4 (Criterion B) |
SURGE | :line-line: ±4kV(internal resistance2Ω); line-ground: ±6kV(internal resistance12Ω) |
EN61000-4-5 (Criterion B) |
Lightning current | line-line/line-ground: 5kA test with 8/20 μs waveform. |
YD/T 1235.2-2002-I 8/20 μs waveform(Criterion C) |
DIP | Dip to 0%Ut, duration 10ms | |
Dip to 0%Ut, duration 20ms | Ut= 220Vac, typical load condition: EN61000-4-11(Criterion B) | |
Dip to 70%Ut,duration 500ms | Ut= 220Vac, typical load condition: EN61000-4-11(Criterion B) | |
Dip to 0%Ut,duration 5000ms | Ut= 220Vac, typical load condition: EN61000-4-11(Criterion C) | |
Dip to 0%Ut, duration 200ms | Criterion B | |
CE | CLASS B, with 2.3dB margin CLASS B with system tested. |
EN55022. |
RE | CLASS A, with 3.6dB margin CLASS B with system tested. |
|
Current harmonics | Meet the requirement for CLASS A products | IEC61000-3-4 |
Voltage fluctuation and flicker | Pst≤1.0; P1t ≤0.65; dc≤3%; dmax≤4%; d(t) ≤3% when duration>200mS |
IEC61000-3-3 |
Others | |
Item | Technical requirement |
Random vibration | Frequency Acceleration spectral density 5~20Hz: 1.0m2/s3; 20~200Hz: -3dB; Totall root mean square acceleration: 0.781Grms; test directions:3 axes. Duration:30min per axe. |
Shock | Waveform : half sine-wave; peak acceleration:180m/s2; pulse width :6ms; test directions:6; 3times per direction. |
Collision | Waveform: half sine-wave; peak acceleration:180m/s2; pulse width :6ms; direction:6 directions; 100times per direction. |
Drop | Weight≤15kg height:100cm Drop at 1 angle, 3 edges and 6 surfaces: 1 angle: The weakest angle shall be selected for drop test, otherwise, angle 2-3-5 3 edges: those intersect at above angle 6 surfaces: External surfaces of packaged unit, 1 time per surface. |
Reliability ( calculated) | ≥ 120,000 Hours |
Acoustic noise | ≤50dB |
Odor | No peculiar and deleterious odor |
moisture proof | GB/T2423.4-1993 ,24~45ºC,95%RH,48h |
Mould proof | GB/T2423.16-1999 CALLS 2 |
Fog proof | GB/T2423.17-1999 96h |
Low pressure test | 5000m |
Safety and Insulation Rating | ||
Item | Requirement | Remark |
Insulation voltage | Input -output:3000Vac/10mA/60S | No flashover or breakdown |
Input -ground:1500Vac/10mA/60S | ||
Output -ground: 500Vdc/10mA/60S | ||
Contact current( PE) | <3.5mA | 264V input, 60Hz. |
Contact current( output) | <0.25mA | |
Grounding impedance | <0.1 | |
Insulation resistance | Under normal atmospheric pressure, relative humidity: 90%; Testing voltage: 500v DC; The insulation resistance of AC&DC(rectifer)-ground,and AC-DC shall not be less than 2MΩ. |
|
Remote Signalling | |||
Item | Signal name | Requirement | Remark |
Input powerdown alarm signal | Vin_Down_ALM | Signal requirements: OC gate output, low level is normal (less than 0.3 V), floated or high level alarm (pull up the signal inside the main control module). The absorb current shall not be less than 5 mA. | |
Temperature detection | Error ≤±5ºC( Remark 1) | I2C protocol adpted. The signal level is 3.3 V, maximum rate is 100k. Address: 0 b1011000x, X for read/write. |
|
Input voltage detection | Error ≤±5% | ||
Input power detection | Error ≤±10% ( Test with typical load condition) |
||
Output voltage detection | Error ≤±5% |
Remote Control Function | ||
Item | Requirement | Remark |
+30V voltage regulating | 30V output by default when there's no I2C voltage regulating signal | Voltage regulating & output shutoff are conducted through I2C protocol. |
Output shutoff control | Anyone of 1-2 output or all outputs can be shutoff by the upper PC through the I2C, the power supply automatically return to normal output (the other output can be shutoff evenif one output be shutoff) for 1 ~ 5 s after the shutoff. To avoid mistaken shutoff, the power supply will execute the shutoff commands after receicing shutoff commands for 3 times in 3s. |