Basic Info.

Model NO.
GPAD700M9-3A
Input Voltage
145-300V
Certification
CE, RoHS, CCC, CB, FCC
Brand
Goldpower
Transport Package
Carton
Specification
202mm*70mm*45mm
Trademark
Goldpower
Origin
China
HS Code
8504401400

Product Description

GPAD700M9-3A is a middle and low duty power supply with AC/DC multi-outputs. Thanks for the latest circuit design, it is compact and of reliable performance. It has the wide range of input voltage and has many functions including short-circuit protection, over-current protection and lightning proof function, accumulator charge. The cooling way is natural conductive. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.
1. Input Requirements
Item Unit Min Typical Max Testing Conditions
Input voltage range Vac 145 220 300  
Input boot-up voltage Vac 145   285  
Input frequency range Hz 45 50 55  
2.Output Requirements
2.1 Basic output requirements
Output voltage Output voltage range Output current range Regulator precession Load regulation Voltage regulation Ripple
+9V 9.10V~9.40V 0A~4A ≤±1% ≤±1% ≤±1% ≤30mV
+9V(JK) 9.1V~9.4V 0A~3A ≤±1% ≤±1% ≤±1% ≤30mV
Lithium Battery 16V~16.4V 0A~0.3A - - - ≤50mV
Remark: measured within the rated voltage input and load, with 0.1UF filmy capacitor and 10UF/50V high frequency electrolytic capacitor output, bandwidth of oscillograph set at 20MHz.
2.2 Other requirements
Item Unit Min Typical Max Testing Conditions
Output Power W - 70    
Output Efficiency % 70 75 - Rated input/output
Temperature coefficient /ºC     ±0.02%  

3 Protection
Item Unit has/not Min Typical Max Recovery characteristics
Input over-voltage protection V YES 300   315  
Recovery point for Input over-voltage protection V YES 285   300
Lack-for-voltage protection of Lithium Battery charge V YES 11.5   12.5  
+9V output limiting-current protection A YES 5   7  
+9V(JK) output limiting-current protection A YES 4   6  
limiting-current protection of Lithium Battery charge A YES 0.3   0.4  
Over-heating protection ºC YES 95   105 Auto recovery
Current for +9V short-circuit protection A YES     7  
Current for +9V(JK) short-circuit protection A YES     6  
Charge and discharge of Lithium Battery     When the normal electricity shut off, it can turn to supply by lithium battery automatically, but it only has +9V(JK), until battery has not enough power, power supply will be protection automatically and shut off battery's electricity. The lithium battery as the standby power supply, it can work on when the normal electricity shut off suddenly,
4 SAFETY
Item Level Standards(or testing conditions)
Insulation voltage
(output to ground)
500Vdc 500Vdc/1Min / Leakage Current≤10mA
Insulation voltage
( input to ground)
1500Vac 1500Vac/1Min / Leakage Current≤10mA
Insulation voltage
( input to output)
3000Vac 3000Vac/1Min / Leakage Current≤10mA
Insulation resistance 10MΩ Under normal atmospheric pressure, and when the relative humidity is 90%, and the testing voltage is DC 500v, for the power supply, the insulation resistance of input to output, input to ground, and output to ground is no less than 10MΩ.
grounding resistance 0.1Ω It will be less than 0.1Ω for a single power supply.
Tangent current 1.5mA It will be less than 1.5mA for a single power supply.
Remark: Remove the discharge tube when is testing.
5 EMC
Item Index requirements Standards
CE CLASS B EN55022
RE CLASS B EN55022
CS LEVEL 2:3V/m EN61000-4-6
RS LEVEL 2:3V/m GB/T17626.2-1998
ESD There is no influence on the operation of power supply when charge on the case after power supply is encased
Tangent discharge:±8KV
Air discharge:±4KV/±15KV
EN61000-4-2
EFT/B LEVEL 3:2KV GB/T17626.4-1998
SURGE LEVEL 3:line-line2KV
          Line-ground4KV
EN61000-4-5
DIP Drop to70%,40%,0%
Holding time 10ms,100ms,500ms etc.
EN61000-4-11
2.6 Other requirements
Item Index requirements Performance
Noise There is no noise. Pass
MTBF 100,000H  
Vibration >Frequency : 5 to 10 Hz
>Amplitude
: 3.5mm,9~200Hz
>Direction
: 3 directions
>Sweep time : 50minutes
(50minute per one way)
> acceleration:10m/s2,

> there is no influence on power supply.
Pass
Shock Half-sine wave,acceleration: 20G,Amplitude 11ms,Direction : 3 directions(X,Y,Z)
 3 times per one direction
Pass
Dustproof Has some function of dustproof Pass
Odor No peculiar smell and deleterious gas Pass

Send your message to this supplier