Environment | |||||
Item | Min. | Typical | Max. | Unit | Remark |
operating temperature | -20 | 25 | 50 | °C | |
Extreme operating temperature | -30 | 25 | 55 | °C | -30°C ~ -20°C can be started with load, extended temperature 50-55°C, and the module linearly reduced power output at 4% / °C |
Humidity | 5 | 95 | % | Relative humidity without condensing | |
Altitude | 0 | 2000 | m |
Input | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Input mode | Three phase five line | Note: The rectifier module has no middle line | |||
Input voltage range | 432 | 480 | 528 | Vac | |
Max. input voltage | 560 | Vac | The module does not work at this input voltage, but it cannot be damaged | ||
Max. input current | 80 | A | Low pressure, full load, per phase | ||
Max. input power | 44 | KVA | Low pressure input, when full load output | ||
Software start time | 3 | 15 | S | The nominal input voltage range of power up to the supply output voltage rises to the set value | |
Input power factor | >0.98 | Rated input, full-load output | |||
>0.97 | Rated input, half-load output | ||||
Input current harmonics | Total harmonics <5% | Rated input, full-load output | |||
Total harmonics <10% | Rated input, half-load output | ||||
Ground way | Protect the power supply housing |
Output | |||||
Item | Min. | Typical | Max. | Unit | Remark |
Rated output voltage range | 200 | 800 | Vdc | ||
Rated output current | 40 | A | 20A * 2 Road | ||
Output rating | 40 | KW | |||
Stable pressure accuracy | -0.5 | +0.5 | % | ||
Valid value of ripple | 1 | % | |||
Dynamic response time | 200 | us | |||
Dynamic response overflush | -0.5 | +0.5 | % | ||
Efficiency | 95 | % | |||
noise | 65 | dB(A) | |||
System heat dissipation mode | air blast cooling |
Protect | |||||
parameter | minimum | typical case | maximum | unit | explanatory note |
Input over-stream protection | With the input overcurrent protection function, the input plastic shell circuit breaker is disconnected during protection. | ||||
Input overpressure protection | 540 | 560 | V | ||
Enter the overvoltage protection recovery | 530 | 540 | V | ||
Input under-pressure protection | 415 | 428 | V | ||
Enter the undervoltage protection restore | 428 | 432 | V | ||
Overtemperature protection of modules | 56 | °C | |||
Output overpressure protection | 1060 | 1080 | V | ||
Output short circuit protection | With output short circuit protection function |