Customization: | Available |
---|---|
Certification: | ISO |
Usage: | Charging Station |
Still deciding? Get samples of US$ 16500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Optional Configuration |
Rectifier module | Optional number | Distribution |
Monitoring system | Remark |
configuration |
GPR75020A (15KW module) |
8pcs | AC input: 3-phase 5wire,250A/3P MCCB; Anti--thunder:3-phase C pole DC output: double gun output mode. Single gun mode output maximum output current is 200A(DC+,DC-) while double gun each 100A EV auxiliary power supply: 12V10A optional(A+,A-) |
Monitoring system | See the module specifications for more detailed information |
Ambient | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temp. range | -20 | 25 | 50 | °C | Certificated within this range |
Extreme operating temp. range |
-40 | 25 | 55 | °C | -40°C ~-20°can be loaded with start ,extended temperature:50 -55°C, The module outputs linearly at 4% / ° C |
Relative humidity | 5 | 95 | % | No condensation on the surface | |
Altitude | 0 | 2000 | m |
Input | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input mode | 3-Phase, 5 Wire (3Ph+N+E) | Note: the charger rectifier module without center line | |||
Nominal input voltage range | 323 | 380 | 437 | Vac | Nominal voltage, certified within this voltage range |
Input operating voltage range | 295 | 380 | 437 | Vac | The input voltage 315-265Vac is linearly reduced from 15KW to 5KW by 2% / V |
Max. input voltage | 560 | Vac | The module could not work but can't be damaged under this input voltage | ||
Max. input current | 240 | A | Low voltage full load ,each phase | ||
Max. input power | 166 | KW | Input 323Vac,output full load. | ||
Soft start time |
5 | 15 | S | The nominal input voltage range is energized to the power supply and the output voltage rises to the set value. | |
Power factor |
>0.98 | Rated input, full load output | |||
>0.97 | Rated input, half load output | ||||
Input current harmonic |
THD<5% | Rated input, full load output | |||
THD<10% | Rated input, half load output | ||||
Grounding method | Protected ground to the power supply case |
Output | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Rated output voltage | 750 | Vdc | |||
Rated output voltage range | 300 | 750 | Vdc | Certificated within this output voltage range | |
Rated output current |
10 | 160 | A | Single gun charging mode | |
5 | 80 | A | Double gun charging mode | ||
Rated output power | 120 | KW | Max. power up to 150KW | ||
Stabilized voltage precision | -0.5 | +0.5 | % | ||
Ripple effective value | 1 | % | |||
Dynamic response time | 200 | us | |||
Dynamic response overshoot | -0.5 | +0.5 | % | ||
Efficiency | 96.4 | % | |||
Noise | 65 | dB(A) | |||
Current-sharing | -5 | 5 | % | Tested when the output current more than 50% | |
Cooling | Forced air cooling |
Mechanical | |
Dimension | (W×H×D) 750*700*1800 mm |
Weight | ≤250Kg(including module) |
Communication protocol | GB/T 18487.1-2015 |
DC Charging Gun | 200A DC *2 |
Function | 1. LAN/WLAN/4G communication 2. IC card/Apps/QR code payment 3. Cloud management |