Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | >2 Years |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product series | |||||||||
Product model | Input range (VDC) |
Output power (W) |
Output voltage (VDC) |
Output (A) |
Ripple & noise (mV) |
full load efficiency (%) Min/Typ. |
Remarks | ||
GPQ120-24S12A | 9-36 | 120 | 12 | 10 | 120 | 87/89 | Standard positive logic | ||
GPQ120-24S12AN | Standard negative logic | ||||||||
GPQ120-24S12AH | Heater is on logic | ||||||||
GPQ120-24S12ANH | Negative logic for radiators | ||||||||
Note: When the input is below 18Vdc, the output power is linearly reduced. When the input is 9Vdc, the output power is 100W. |
|||||||||
Input characteristics | |||||||||
Item | Technical indicators | Min. | Typ. | Max. | unit | ||||
Maximum input current | 9V input voltage, full load output | -- | -- | 18 | A | ||||
No-load input current | Rated input voltage | -- | -- | 20 | mA | ||||
Input voltage (max. 1 sec.) | Entering outside this range may cause permanent damage | -0.7 | -- | 50 | VDC | ||||
Starting voltage | -- | -- | 9 | ||||||
Input under-voltage protection | No-load test, full load test will pre-emptive overcurrent protection | -- | -- | 8.5 | |||||
Remote Control Foot (CNT) | Positive logic: CNT is suspended or connected to 3.5-15V to start up, and connected to 0-1.2V voltage to shut down | reference voltage -VIN | |||||||
Negative logic: CNT is suspended or connected to 3.5-15V for shutdown, and connected to 0-1.2V voltage for startup |
Output characteristic | |||||
Item | Technical indicators | Min. | Typ. | Max. | unit |
Output voltage accuracy | Nominal input voltage, from 10% load | -- | ±0.5 | ±1.0 | % |
Linear regulation rate | Full load, input voltage from low voltage to high voltage | -- | ±0.1 | ±0.2 | |
Load regulation rate | Nominal input voltage, from 10% to 100% load | -- | ±0.2 | ±0.5 | |
Transient recovery time | 25% load step change (step rate 1A/50uS) | -- | 200 | 250 | uS |
Transient response deviation | -5 | -- | 5 | % | |
Temperature drift coefficient | loaded to capacity | -0.02 | -- | +0.02 | %/ºC |
Ripple & noise | 20M bandwidth, external 220uF above capacitor test | -- | 100 | 120 | mVp-p |
Output voltage adjustable (TRIM) | -20 | -- | +10 | % | |
Output voltage remote compensation (Sense) | -- | -- | 5 | % | |
Overtemperature protection | Maximum surface temperature of the product metal substrate | 105 | 115 | 125 | ºC |
Overvoltage protection output | 125 | -- | 140 | % | |
Overcurrent protection output | 11 | -- | 22 | A | |
Output short circuit protection | Hiccups, sustainable, self-recovery |