Customization: | Available |
---|---|
Output Type: | Triple |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Unit | Min | Typical | Max | Testing Conditions |
Input voltage range | Vac | 165 | 220 | 295 | |
Range of input voltage frequency | Hz | 47 | 50 | 63 |
Output voltage | Output current range | Regulator precession | Load regulation | Voltage regulation | Ripple +Noise |
+28V | 0.3A~8A | ≤±2% | ≤±2% | ≤±1% | ≤150mV |
+6V | 0A~10A | ≤±2% | ≤±2% | ≤±1% | ≤70mV |
+9.5V | 0A~1A | 8.9~9.8V | - | - | ≤90mV |
Item | Unit | Min | Typical | Max | Testing Conditions |
Output Power | W | - | 280 | Natural cooling/full load | |
Output Efficiency | % | 80 | - | Rated input/output | |
Temperature coefficient | /ºC | ±0.02% |
Item | Unit | Min | Typical | Max | Recovery characteristics |
Input wanting voltage protection | V | 130 | 145 | +28V with 3A @ testing | |
The recovery point of input wanting voltage protection | V | 150 | 165 | ||
Input over-voltage protection | V | 300 | 320 | +28V with 3A @ testing | |
The recovery point of input over-voltage protection | V | 290 | 305 | ||
+28V output over-voltage protection | V | 29 | - | 31 | auto recovery |
+28V output limited current protection | A | 11 | 15 | auto recovery | |
+6V output limited current protection | A | 12 | 16 | ||
+9.5V output limited current protection | A | 1.5 | 5 | ||
Over-heating protection | ºC | 95 | 105 | auto recovery | |
Short-current protection | - | - | - | It can be short-circuit for a long time, and auto recovery |
Item | Level | Standards(or testing conditions) |
Insulation voltage (input to output) |
1500Vac | 1500Vac /1Min / Leakage Current≤10mA |
Insulation voltage ( input to ground) |
1500Vac | 1500Vac /1Min / Leakage Current≤10mA |
Insulation voltage (output to ground) |
500Vdc | 500Vdc /1Min / Leakage Current≤10mA |
Insulation resistance | 10MΩ | Under normal atmospheric pressure, and when the relative humidity is 90%, and the testing voltage is DC 500v, for the power supply, the insulation resistance of input to output, input to ground, and output to ground is no less than 10MΩ. |
Item | Index requirements | Standards |
CE | CLASS B | EN55022 |
RE | CLASS B | EN55022 |
ESD | There is no influence on the operation of power supply when charge on the case after power supply is encased Tangent discharge:±6KV Air discharge:±8KV |
EN61000-4-2(B) |
Item | Index requirements | Performance |
Noise | The noise of power supply should be less than 55dB(A), the condition is in the range of input voltage and output voltage and current, the distance is 1 meter from front , back, right and left, and 1.5 meter from upper and underside. | Pass |
MTBF | 100,000H | |
Vibration | >Frequency : 5 to 10 Hz >Amplitude : 3.5mm,9~200Hz >Direction : 3 directions >Sweep time : 50minutes(50minute per one way) > acceleration:10m/s2, > there is no influence on power supply. |
Pass |
Shock | Half-sine wave,acceleration: 20G,Amplitude 11ms,Direction : 3 directions(X,Y,Z) 3 times per one direction |
Pass |
Dustproof | Has some function of dustproof | Pass |
Odor | No peculiar smell and deleterious gas | Pass |