1000va, 2000va, 3000va Industrial Inverter

Transport Package: Carton
Trademark: Goldpower
Origin: China
Samples:
US$ 150/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Product Description

 
 
   






GPDA1000VA-A
Input:40-60Vdc;  Output :220Vac; Capacity:1000VA








 
       
     
 
   


















 





ISO9001-2000 Certified
Professional Power Supply Manufacturer
Shenzhen Goldpower Tech Co., LTD

Address: 1301 Bldg A, New-tech Plaza Tian'an Cyber Park, Futian District,     Shenzhen City.
Tel: +86 755-83432128  83433146   Fax: +86 755-83432651 83437956
Website: http://szgoldpower.en.made-in-china.com   Postal code: 518040

Preface



 Welcome to use GPDA1000VA-A,GPDA1000VA-A from Gold Power, consisting of two outputs, bypass AC input, with RS485 com port. Due to the latest circuit design, it is compact and of reliable performance, and the system is equipped with protections against input reversed polarity, over temperature, output short-circuit, over-current and over-voltage. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.
Statement
  1. The performance of GPELU4806-10 embedded power system is detailed in the specification. Please learn the specification before any operation is conducted in compliance with safety rules. Our warrant will not apply to any damage of product caused by improper operation or utilization out of range specified in this specification.
  2. The information in this specification is subject to change without any notice.
Safety rules
 
 
High voltage!
AC input line is high voltage operating line. Be sure that the AC input is cut off before implementing any operations. Warning signs shall be tagged to the switches that should not be touched during operating process.
 
Caution!  AC terminals and other unnecessarily bare part shall be strictly insulated.
 
Caution! The device shall be securely grounded before power-on.
Caution! The module is hot-swappable; please make sure that all indicators on module panel is under state of off before the module is inserted.
 
  Any operation at AC & high voltage under lightning is forbidden.


1. Parameters


 
Input
Parameter Min. Typ Max. Unit Remarks
DC input Working voltage range 40   60 Vdc  
Rated voltage   48   Vdc  
Rated current     30 A Rated input, Rated output.
Max surge current     45 A rated 150%
AC output Working voltage range 200   240 Vac  
Rated voltage   220   Vac  
Rated current     5 A  
 
Output
Parameter Min. Typ Max. Unit Remarks
Inverter Output Rated voltage   220   Vac Full input range
Rated current   4.6   A  
Voltage accuracy     ±5 % Full input range
Rated Frequency 49 50 51 Hz  
Rated capacity     1000 VA  
Rated power     1000 W  
Efficiency 85     % Rated working condition
Power factor 0.8       Rated working condition
Dynamic transient recovery time     60 ms  
Waveform Sine wave THD<3%(linear load)
Sine waveTHD<8%(non-linear load)
Overload capacity 105~125% load for more than10 mins, 125~150%load for more than10 secs.
Output current peak ratio 3:1
Output QTY Two AC outputs
Bypass AC output  Output voltage range 200   240 Vac Changes according to AC voltage's changing.
Rated voltage   220   Vac  
Rated current     5 A  
 Inverter switches to grid's time.     20 ms Rated load
Grid switches to inverter's time.     100 ms Rated load
Output description Share the same output terminals to the inverter. When there is AC input, use the grid. When AC fail, automatically switch to the inverter and then power the equipments.
               


1. Parameters
 
Protections
Parameter Min. Typical Max. Unit Remarks
Inverter DC input UVP set point 36     Vdc  
DC input UVP recovery point     40 Vdc Recover in 1 min
DC input UVP tolerance 2     Vdc  
DC input OVP set point     66 Vdc  
DC input OVP recovery point 60     Vdc Recover in 1 min
DC input OVP tolerance 2     Vdc  
OCP OCP without auto-recovery function.
OTP Cut off power when the heat sinking is over temperature.
Anti-reverse connection Inverter will not work when reverse connecting the input.
Short protection When inverter shorts, it'll auto restart every 1 min, if the inverter become normal, it can auto-recover. If it short for long time, the inverter will stop working.
Output OCP When inverter is over current, it'll auto restart every 1 min, if the inverter become normal, it can auto-recover. If it is over current for long time, the inverter will stop working.
 Alarm When there is input abnormal, overload, short, inverter malfunction, can hear the buzzer.
Bypass input Input OCP  Can't auto-recover.
 
Ambient requirements
Parameters Min Typ. Max Unit Remark
Operating temp -20   +55 °C  
Storage temp -25   +70 °C  
Humidity 0   95 % Relative humidity, no condensing
Altitude     1500 m Complied with GB3859.2-93
Cooling Natural cooling
 
Insulation rating
Parameter Requirement Remark
Insulating strength Input - output:1500Vac/10mA//1min No flashover or breakdown
 
Input -earth:1500Vac/10mA//1min
Output-earth:500Vac/10mA//1min
Insulation resistance @ normal atmospheric pressure, relative humidity: 90%  Testing voltage: 500v dc  The insulation resistance of input-output, input-ground, output-ground shall not be less than 10MΩ
 
EMC
Conducted emission Complied with YD/T983-1998 class A
Radiated emission Complied with YD/T983-1998 class A
 Immunity Complied with YD/T983-1998  class A
Reverse irrigation broadband noise current relative value <10%
Noise <50dB(1m)
Dedust Functional
Smell No harmful gas
1. Parameters

 
Mechanical specifications
L*W*H (mm) Refer to following chart
Weight(kg) 4kg
\* MERGEFORMAT
























































2. Signals


2.1,LED definition
 
Alarms
No. Status LED indicator  Remark
1 Green flicker   Normal Report input voltage, current, temperature through 485 port, together with  input OVP,UVP, OCP, OTP, fan fail,, etc.
Red off
Purple off
2 Green on Input UVP, OVP, short, overload, OTP, protection. Fan fail
Red flicker
Purple off
3  Green off Malfunction
Red flicker
Purple off
4  Green off Input reverse connection, inverter malfunction.
Red off
Purple off
5  Green on  AC grid normal.
Red off
Purple on



2.2 Terminals' definition

\* MERGEFORMAT































3. Installation

\* MERGEFORMAT 3.1 Embedded



















Dimension

Installation method:
Insert the inverter into the specific position, in order to guarantee it's positioned properly, the hungers should be screwed with 4 of M6 screws.

\* MERGEFORMAT 3.2 wall-mounted type











Dimension
Installation method:
As shown on above drawing, you need to fill in the wall with 4 of M6 setscrews, and then fix the inverter on to the wall.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now