556W Battery Charger 48V 10A

Product Details
Customization: Available
Rated Power: 556W
Charging Current: 48V/10A
Still deciding? Get samples of US$ 10/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO14001:2015, ISO45001:2016, IATF16949
Find Similar Products

Basic Info.

Model NO.
GPCH4810A
Transport Package
Carton
Trademark
Goldpower
Origin
China

Product Description

Ambient
Parameters Min Typical Max Unit Remark
Operating temperature -40   55 °C The charger is able to start @-40°C.
Extended operating temperature 55   75 °C Auto derating
Storage temperature Storage temperature -45   85 °C  
Humidity 5   95 % Relative humidity, no condensing
Altitude -60
 
  4000
 
m
 
Horizontally, the unit operates with max temp of 65°C, which will derate 1.5°C per rise of 1000m.
-200   13000 ft If the operation is above 2500m (5000 ft),
the max operation temperature derates 2°C. per rise of 305m (1000 ft.)
Atmospheric pressure 70   106 KPa  
Cooling         Natural cooling
Noise   45   dB  

 
Input
Parameter Min. Typical Max. Unit Remark
Input voltage range 90 120/230 300 Vac  
Input frequency 45 50 65 Hz  
Input current (Max.)
 
    6.7 A 120Vac
    2.8 A 230Vac
Inrush current     13.3 A  
Power Factor 0.99       Rated load, 120Vac
0.98       Rated load, 120Vac
 
Output
Parameter Min. Typical Max. Unit Remark
 Output voltage range 40   56.5 Vdc  
 Output current range 0 10   A  
Load regulation     ±1 %  
Regulation     ±1 %  
Line regulation     ±0.5 %  
Ripple (Vp-p)     200 mV Rated input/output, with 0.1uF film capacitor and 10uF high frequency electrolyte capacitor applied, oscilloscope band width is 20MHz.
Output power     556 W Rated input/ full load output
Output efficiency 92     % Rated input/ full load output
Start up time 3   8 S Rise up to 40V~48V
Start up overshoot     5 %  
Transient response overshoot     ±5 %  
Recovery time for transient response     200 us 25%~50%~75% Load variation
Temperature coefficient     ±0.02 %/ºC  
Float charge voltage   54   V  
Equalizing charge voltage   56.5   V  
Temperature compensation         The voltage of equalizing/float charge decreases 60mV per 1ºC of rise when the temperature is more than 40ºC.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now