Customization: | Available |
---|---|
Input Mode: | 3-Phase, 5 Wire(3pH+N+E) |
Input Operating Voltage Range: | 295~437VAC |
Still deciding? Get samples of US$ 5000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Optional Configuration |
Rectifier module | Optional number | Distribution |
Monitoring system | Remark |
configuration |
GPR75020A | 2pcs | AC input: 3-phase 5wire,63A/4P air switch; Anti--thunder:3-phase C pole DC output: the gun mode output maximum output current is 40A(DC+,DC-) EV auxiliary power supply: 12V10A/24V5A optional(A+,A-) |
Monitoring system | See the module specifications for more detailed information |
Ambient | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temp. range | -20 | 25 | 50 | °C | Certificated within this range |
Extreme operating temp. range |
-40 | 25 | 55 | °C | -40°C ~-20°can be loaded with start, extended temperature:50 -55°C, The module outputs linearly at 4% / ° C |
Relative humidity | 5 | 95 | % | No condensation on the surface | |
Altitude | 0 | 2000 | m |
Input | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input mode | 3-Phase, 5 Wire (3Ph+N+E) | Note: the charger rectifier module without midcourt line | |||
Nominal input voltage range | 323 | 380 | 437 | Vac | Nominal voltage, certified within this voltage range |
Input operating voltage range | 295 | 380 | 437 | Vac | The input voltage 315-265Vac is linearly reduced from 15KW to 5KW by 2% / V |
Max. input voltage | 560 | Vac | The module could not work but can't be damaged under this input voltage | ||
Max. input current | 60 | A | Low voltage full load ,each phase | ||
Max. input power | 32 | KVA | Input 323Vac,output full load. | ||
Soft start time |
5 | 15 | S | The nominal input voltage range rises to the set value of the output voltage. | |
Power factor |
>0.98 | Rated input, full load output | |||
>0.97 | Rated input, half load output | ||||
Input current harmonic |
THD<5% | Rated input, full load output | |||
THD<10% | Rated input, half load output | ||||
Grounding method | Protective ground to the power supply case |
Output | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Rated output voltage | 750 | Vdc | |||
Rated output voltage range | 300 | 750 | Vdc | Certificated within this output voltage range | |
Rated output current | 2 | 40 | A | ||
Rated output power | 30 | KW | |||
Stabilized voltage precision | -0.5 | +0.5 | % | ||
Ripple effective value | 1 | % | |||
Dynamic response time | 200 | us | |||
Dynamic response overshoot |
-0.5 | +0.5 | % | ||
Efficiency | 95.8 | % | |||
Noise | 65 | dB(A) | |||
Current-sharing | -5 | 5 | % | Tested when the output current more than 50% | |
Cooling | Forced air cooling |
Protection | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input over current protection |
With input over current protection function, the input circuit breaker trip during protection. | ||||
Input over voltage protection |
455 | 465 | V | ||
Input over voltage Protection recovery |
445 | 455 | V | ||
Input under voltage protection |
250 | 264 | V | ||
Input under voltage protection recovery |
280 | 305 | V | ||
Module over temp. protection |
56 | °C | Auto recovery after the module temperature is reduced, | ||
Output over voltage protection |
765 | 785 | V | Overvoltage lock, the module re-unlocked | |
Output over current protection |
44 | A | Over current, or constant current | ||
Output short circuit protection |
With short circuit protection function | ||||
Fan fault protection | Any fan failure corresponding to the power module no output. | ||||
Battery anti-reverse protection |
When the output charging battery is reversed, the system has no output | ||||
Insulation detection | With insulation detection protection function. | ||||
System abnormal protection |
During the charging process, in an emergency (such as starting the emergency stop switch, communication failure with the electric vehicle battery management system, control guidance failure, etc.), the charger should immediately disconnect the output contactor, and through the discharge circuit within 1S The charge interface voltage drops below 60VDC. |
Mechanical | |
Dimension(W×H×D) | 400 mm×750 mm×650mm |
Weight | ≤60Kg(including module) |