Model NO.
GPDA1000VA-I
Output Power
1000W
Grid Type
off-Grid Inverter
Output Type
Single
DC Rated Input Voltage
48VDC
DC Input Current Rating
30A
AC Rated Input Voltage
220VAC
AC Input Rated Current
5A
Rated Output Voltage
220VAC
Rated Output Current
4.6A
Nominal Capacity
1000va
Machine Efficiency
85%
AC Bypass Rated Output Voltage
220VAC
AC Bypass Rated Output Current
5A
Transport Package
Carton
Specification
481.6× 270× 88(mm)
Trademark
Goldpower
Origin
Shenzhen
HS Code
8504401990
Production Capacity
1000000 Pieces

Product Description

GPDA1000VA-I is one model from Goldpower Off-Grid inverter series, with AC bypass input and RS485 communication

Feature:
  1. Flexible and efficient
  2. Easy installation
  3. Safe and reliable
Specification:
           Model    GPDA1000VA-I
                    project           parameter
Input parameters Dc input DC working voltage range           40~60Vdc
 
Rated input voltage            48Vdc
input current rating 30A
Ac input AC voltage range 175~265Vac
Rated input voltage 220Vac
Input Rated current 5A
Output parameters

 
Inverter output rated output voltage 220VAC
 
Rated output current 4.6A
output voltage accuracy ±5%
Rated output frequency 49~51Hz
Nominal capacity 1000VA
machine efficiency 85%
Output way Two way communication output
Ac bypass output output voltage range
 
175~265Vac
 
rated output voltage 220Vac
Rated output current 5A
Protection Input over-current protection inlay
 
Over temperature protection inlay
 
Meter protection inlay
Short circuit protection inlay
Output over-current protection inlay
Ac bypass input over-current protection inlay
 
Alarm function inlay
Conventional parameters
 
Operating temperature  -20~55°C
 
Relative humidity 5~95%
Altitude 1500m
Cooling method Natural cold
Noise <50dB
Dimensions 481.6×270×88(mm)
Weight 5kg
Certification UL/TUV/CE