Customization: | Available |
---|---|
Usage: | LED Power Supply |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.1 Input characteristics | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 264 | Vac | |
Input current | 6 | A | |||
Input impulse current | 60 | A | 220VAC input, output full load | ||
Input frequency | 47 | 50 | 63 | Hz | Full range normal operation |
power factor | 0.95 | 220VAC input, output full load |
1.2 output characteristic | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
output voltage | +5V | Vdc | Configure 3.8v-5.5v output voltage according to customer requirements | ||
Output current range | 0 | 80 | A | ||
Ripple (peak to peak) | 200 | m Vp-p | At the rated input / output, add one 0.1 μ f ceramic chip capacitor and one 10 μ f high frequency electrolytic capacitor, and measure the bandwidth at 20MHz. Ripple less than 300 m Vp-p at low temperature below - 20 ºC | ||
Load adjustment rate | ±2 | % | |||
Source adjustment rate | ±0.5 | % |
1.3 Other output characteristics | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
output power | 400 | W | |||
Output efficiency | 91 | % | 220 VAC input, 50% - 100% output | ||
temperature coefficient | ±0.03 | %/ºC | |||
Switching machine overshoot | ±10 | % | |||
Dynamic response overshoot | ±5 | % | 25% - 50% - 25% or 50% - 75% - 50% load change, load mutation rate is 0.1a/μ s, calculated as the part beyond the output voltage stabilization accuracy range | ||
Dynamic response recovery time | 200 | uS | |||
Power on output delay | 2 | S |
1.4 Protection characteristics | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Output overvoltage protection | 7 | V | 220VAC input, burping | ||
Output overcurrent protection | 110 | A | Burp, self recovery | ||
Short circuit protection | Yes | Short circuit for a long time, self recovery | |||
Over temperature protection | 70 | °C | It can be short circuited for a long time, and can recover the ambient temperature of the power supply by itself. The protection mode is burping, which can recover itself |