DC-DC Full Brick Isolation Converter 66-160V 24V/600W

Product Details
Customization: Available
Output Type: Single
Warranty: >2 Years
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO14001:2015, ISO45001:2016, IATF16949
  • DC-DC Full Brick Isolation Converter 66-160V 24V/600W
  • DC-DC Full Brick Isolation Converter 66-160V 24V/600W
Find Similar Products

Basic Info.

Output Power
>500W
Input Voltage
Input:66-160
Modulation System
PWM

Product Description

Product series
 Product model  Input range
(VDC)
 Output power
(W)
 Output voltage
(VDC)
 Output
(A)
Ripple & noise
(mV)
 full load efficiency (%)
Min/Typ.
 Remarks
GPF600-110S24D 66-160 600 24 25 240 89/91 Standard positive logic
GPF600-110S24DN Standard negative logic
GPF600-110S24DH Heater is on logic
GPF600-110S24DNH Negative logic for radiators
 
 Input characteristics
 project  going Min. Typ. Max.  unit
Maximum input current 6Vdc input voltage, full load output -- -- 12 A
No-load input current Rated input voltage -- -- 20 mA
Input voltage (max. 1 sec.) Entering outside this range may cause permanent damage -0.7 -- 185 VDC
 starting voltage   -- -- 66
Input under-voltage protection No-load test, full load test will pre-emptive overcurrent protection -- -- 64
Remote Control Foot (CNT) Positive logic: CNT is suspended or connected to 3.5-15Vdc to start up, and connected to 0-1.2Vdc voltage to shut down  reference voltage -VIN
Negative logic: CNT is suspended or connected to 3.5-15Vdc for shutdown, and connected to 0-1.2Vdc voltage for startup
 
 output characteristic
 project  going Min. Typ. Max.  unit
Output voltage accuracy Nominal input voltage, from 0% to 100% load -- ±0.5 ±1.0 %
Linear regulation rate Full load, input voltage from low voltage to high voltage -- ±0.2 ±0.5
Load regulation rate Nominal input voltage, from 10% to 100% load -- ±0.2 ±0.5
Transient recovery time 25% load step change (step rate 1A/50uS) -- 200 250 uS
Transient response deviation -5 -- 5 %
Temperature drift coefficient  loaded to capacity -0.02 -- +0.02 %/ºC
Ripple & noise 20M bandwidth, external 470uF above capacitor test -- 200 240 mVp-p
Output voltage adjustable (TRIM)    -20 -- +10 %
Output voltage remote compensation (Sense)   -- -- 5 %
Overtemperature protection Maximum surface temperature of the product metal substrate 105 115 125 ºC
Overvoltage protection output   125 -- 140 %
Overcurrent protection output  27.5 -- 35 A
Output short circuit protection Hiccups, sustainable, self-recovery

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier