Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | >2 Years |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product series | |||||||||||
Product model | Input range (VDC) |
Output power (W) |
Output voltage (VDC) |
Output (A) |
Ripple & noise (mV) |
full load efficiency (%) Min/Typ. |
Remarks | ||||
GPF600-110S24D | 66-160 | 600 | 24 | 25 | 240 | 89/91 | Standard positive logic | ||||
GPF600-110S24DN | Standard negative logic | ||||||||||
GPF600-110S24DH | Heater is on logic | ||||||||||
GPF600-110S24DNH | Negative logic for radiators | ||||||||||
Input characteristics | |||||||||||
project | going | Min. | Typ. | Max. | unit | ||||||
Maximum input current | 6Vdc input voltage, full load output | -- | -- | 12 | A | ||||||
No-load input current | Rated input voltage | -- | -- | 20 | mA | ||||||
Input voltage (max. 1 sec.) | Entering outside this range may cause permanent damage | -0.7 | -- | 185 | VDC | ||||||
starting voltage | -- | -- | 66 | ||||||||
Input under-voltage protection | No-load test, full load test will pre-emptive overcurrent protection | -- | -- | 64 | |||||||
Remote Control Foot (CNT) | Positive logic: CNT is suspended or connected to 3.5-15Vdc to start up, and connected to 0-1.2Vdc voltage to shut down | reference voltage -VIN | |||||||||
Negative logic: CNT is suspended or connected to 3.5-15Vdc for shutdown, and connected to 0-1.2Vdc voltage for startup |
output characteristic | |||||
project | going | Min. | Typ. | Max. | unit |
Output voltage accuracy | Nominal input voltage, from 0% to 100% load | -- | ±0.5 | ±1.0 | % |
Linear regulation rate | Full load, input voltage from low voltage to high voltage | -- | ±0.2 | ±0.5 | |
Load regulation rate | Nominal input voltage, from 10% to 100% load | -- | ±0.2 | ±0.5 | |
Transient recovery time | 25% load step change (step rate 1A/50uS) | -- | 200 | 250 | uS |
Transient response deviation | -5 | -- | 5 | % | |
Temperature drift coefficient | loaded to capacity | -0.02 | -- | +0.02 | %/ºC |
Ripple & noise | 20M bandwidth, external 470uF above capacitor test | -- | 200 | 240 | mVp-p |
Output voltage adjustable (TRIM) | -20 | -- | +10 | % | |
Output voltage remote compensation (Sense) | -- | -- | 5 | % | |
Overtemperature protection | Maximum surface temperature of the product metal substrate | 105 | 115 | 125 | ºC |
Overvoltage protection output | 125 | -- | 140 | % | |
Overcurrent protection output | 27.5 | -- | 35 | A | |
Output short circuit protection | Hiccups, sustainable, self-recovery |