Basic Info.

Output Power
101 - 200W
Input Voltage
Input:9~40
Modulation System
PWM

Product Description

Main specifications of the products:
 
Input voltage range (Vdc) Output Voltage (Vdc) Output current
(A)
Output voltage adjustable range (%) Output Ripple and Noise
(mVp-p)
Typical efficiency at full load (%)
9~40 12.0 0~16.66 -20~+10 100 93.5
Output characteristics
Output voltage accuracy 11.70 12.00 12.30 Vdc  
Range of output voltage calibration value 11.82 12.00 12.18 Vdc  
Output voltage adjustable range -20   +10 %Vo  
Voltage Adjustment Rate     ±0.2 %Vo Output at full load
Load Adjustment Rate     ±0.5 %Vo Vin=24Vdc
Efficiency 50% load 93.0 94.0   % Vin=24Vdc,Tcase=25ºC,heat sink attached to housing;
  100% load 92.5 93.5   %  
Output current 0   16.66 A  
Output overcurrent protection 17.5 20.5 23.5 A Vin=16~40Vdc,Hiccups, auto-recoverable;
Output Overvoltage Protection 14.5 16.5 18.5 Vdc Hiccups, auto-recoverable;
Output Ripple and Noise   100   mVp-p Test method with reference to figure(11)
Output external capacitor 660 1000   µF polymer tantalum or solid-state capacitors, or low-ESR electrolytic capacitors (-55°C), with withstanding voltage ≥ 25V;
Output capacitive load 3300     µF pure resistive load test, tantalum capacitor or low ESR electrolytic capacitor, voltage withstand ≥ 25V;
Input power-on delay time   200 250 ms The time from input power-on to output voltage rise to 10%;
ON/OFF power-on delay time   5 10 ms The time from ON/OFF power-on to output voltage rise to 10%;
Output voltage rise time   10 30 ms The time for the output voltage to rise from 10% to 90%;
Switching output voltage overshoot amplitude     ±3 %Vo  
Remote switch-on overshoot amplitude     ±3 %Vo  
Transient Response Overshoot amplitude   300 350 mV di/dt=1A/µs,25%-50%-25%,load step change;
  Recovery time   500 800 µs  
  Overshoot amplitude   300 350 mV di/dt=1A/µs,50%-75%-50%,load step change;