900W Multiple Output Customized Switching Power Supply is a High Efficiency financial self-service equipment power supply,with short-curcuit protection,over current protection,output over voltage protection and so on.
Features:
1. Multiple Outputs
2. Applied to global grid
3. Low consumption for standby,high efficiency up to 85%,cost-effective.
4. Support hot plug,module designed,the installation easy to maintain,complete protection.
5.
High reliability,MTBF>20,0000Hours.
Specification:
Input |
Parameter |
|
Min. |
Typ. |
Max. |
Unit |
Remark |
input voltage |
|
180 |
|
264 |
Vac |
|
Input startup voltage range |
|
180 |
|
264 |
Vac |
|
Input frequency |
|
|
50/60 |
|
Hz |
|
Max. input current |
|
|
|
6 |
A |
|
Max. input inrush current |
|
|
|
40 |
A |
|
Power factor |
|
0.90 |
|
|
|
|
Output |
Parameter |
|
Min. |
Typ. |
Max. |
Unit |
Remark |
DC output voltage range |
24VS1-1 |
24.25 |
25 |
25.75 |
Vdc |
+25.0V±3%
|
24VS2 |
24.25 |
25 |
25.75 |
24VS1-2 |
24.25 |
25 |
25.75 |
24V1 |
24.25 |
25 |
25.75 |
24V2 |
24.25 |
25 |
25.75 |
24V3 |
24.25 |
25 |
25.75 |
24V4 |
24.25 |
25 |
25.75 |
DC output current range |
24VS1-1 |
0 |
|
2.9 |
A |
|
24VS2 |
0 |
|
1.4 |
24VS1-2 |
0 |
|
2.5 |
24V1 |
0 |
|
2.3 |
24V2 |
0 |
|
4 |
24V3 |
0 |
|
5 |
24V4 |
0 |
8 |
17.9 |
Ripple+Noise(peak to peak) |
24VS1-1 |
|
|
290 |
mV |
|
24VS2 |
|
|
290 |
24VS1-2 |
|
|
290 |
24V1 |
|
|
290 |
24V2 |
|
|
290 |
24V3 |
|
|
290 |
24V4 |
|
|
290 |
Output power |
|
|
|
880 |
W |
|
Output efficiency |
85 |
|
|
|
% |
|
Turn-on/down overshoot |
|
|
|
25 |
V |
|
Output raise time |
|
|
|
200 |
mS |
|
Ambient |
Parameter |
|
Min. |
Typ. |
Max. |
Unit |
Remark |
Operating temperature |
|
0 |
|
55 |
ºC |
|
Storage temperature |
|
-20 |
|
65 |
ºC |
Operating Relative humidity |
|
10 |
|
90 |
% |
Storage relative humidity |
|
8 |
|
90 |
% |
Altitude |
|
0 |
|
5000 |
m |
Atmosphere pressure |
|
70 |
|
106 |
KPa |
Cooling |
Inside the fan comes with heat |
Protection |
Input under voltage protection |
130 |
|
140 |
Vac |
|
Input under voltage protection recovery |
140 |
|
150 |
Input over voltage protection |
276 |
|
288 |
Input over voltage protection recovery |
262 |
|
272 |
DC Output over voltage protection |
26 |
|
36 |
DC Output limited current protection |
24VS1-1 |
5.3 |
|
8.5 |
A |
Auto recovery |
24VS2 |
3 |
|
5 |
24VS1-2 |
3 |
|
5 |
24V1 |
3.8 |
|
6 |
24V2 |
5 |
|
8 |
24V3 |
12 |
|
16 |
24V4 |
28 |
|
34 |
Short-curcuit protection |
Long-term short-curcuit,auto recovery. |
Over temperature protection |
TH2:88~98ºC,protection
<85ºC,recovery |
ºC
|
|
EMC&Others |
Parameter |
Standard requirement |
Radiation Emission(CE) |
EN55022 - Class B |
Conduction interference(RE) |
EN55022 - Class B |
surge |
EN61000-4-5 LEVEL 3,line-line2KV,line-earth2KV |
Electrostatic discharge (ESD) |
EN61000-4-2 Contact discharge±6KV,Air discharge±8KV |
Radiation immunity (RS) |
EN/IEC 61000-4-3 Test frequency:80MHz~1000MHz,1.4GHz~2GHz;Electric field strength:3V/m; Amplitude modulation:80%AM(1KHz) |
Conduction immunity (CS) |
EN/IEC 61000-4-6 Test frequency:0.15MHz~80MHz,Test strength:3V;Amplitude modulation:80%AM(1KHz) |
Fast transient bursts |
EN/IEC 61000-4-4 ±2KV |
Voltage sags andshort interruptions |
EN/IEC61000-4-11 Fell to 70% UT,Duration 500ms;Fell to 0% UT,Duration 20ms;Criterion B,Criterion C |
vibration |
Project |
Operating |
During shipping |
Vibration |
4.9m/s2(0.5G) |
19.6m/s2(2G) |
Shock |
49m/s2(5G) |
98m/s2(10G) |
|
Anti-moisture |
GB/T2423-1993 Damp heat test,24~45ºC95%RH,48h |
Anti - mold |
GB/T2423.16-1999 Mold experiment, Level2 |
MTBF |
≥200,000h |
Working lifetime |
65000H |
Return rate of year |
≤1% |
Smell |
No semll harmful to health |
Environment protection |
RoHS&VCCI-A |
Safty |
UL/3C |