900W Multiple Output Customized Switching Power Supply for ATM

Product Details
Customization: Available
Output Type: Multiple
Warranty: 2 Years
Still deciding? Get samples of US$ 150/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO14001:2015, ISO45001:2016, IATF16949
  • 900W Multiple Output Customized Switching Power Supply for ATM
  • 900W Multiple Output Customized Switching Power Supply for ATM
  • 900W Multiple Output Customized Switching Power Supply for ATM
  • 900W Multiple Output Customized Switching Power Supply for ATM
  • 900W Multiple Output Customized Switching Power Supply for ATM
  • 900W Multiple Output Customized Switching Power Supply for ATM
Find Similar Products

Basic Info.

Model NO.
GPAD881M24-7B
Input Voltage
180~264VAC
Connection Mode
Parallel Switching Power Supply
Starting Mode
Self-excited Switching Power Supply
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Modulation System
PFM
Certification
CCC
Brand
Goldpower
Input Frequency
50/60Hz
Power Factor
0.90
Output Voltage
24V
Output Current
2.9A, 1.4A, 2.5A, 2.3A, 4A, 5A, 17.9A
Operating Temperature
0~55ºC
Storage Temperature
-20~65ºC
Output Efficiency
85%
Mtbf
≥200,000h
Transport Package
Carton
Specification
250*250*60 mm
Trademark
Goldpower
Origin
Shenzhen
HS Code
8504401990
Production Capacity
6000000/Year

Product Description

900W Multiple Output Customized Switching Power Supply is a High Efficiency financial self-service equipment power supply,with short-curcuit protection,over current protection,output over voltage protection and so on.

Features:
1. Multiple Outputs
2. Applied to global grid
3. Low consumption for standby,high efficiency up to 85%,cost-effective.
4. Support hot plug,module designed,the installation easy to maintain,complete protection.
5. High reliability,MTBF>20,0000Hours.

Specification:
Input 
Parameter   Min. Typ. Max. Unit Remark
input voltage   180   264 Vac  
Input startup voltage range   180   264 Vac  
Input frequency     50/60   Hz  
Max. input current       6 A  
Max. input inrush current       40 A  
Power factor   0.90        
Output 
Parameter   Min. Typ. Max. Unit Remark
DC output voltage range 24VS1-1 24.25 25 25.75 Vdc +25.0V±3%
 
24VS2 24.25 25 25.75
24VS1-2 24.25 25 25.75
24V1 24.25 25 25.75
24V2 24.25 25 25.75
24V3 24.25 25 25.75
24V4 24.25 25 25.75
DC output current range 24VS1-1 0   2.9 A  
24VS2 0   1.4
24VS1-2 0   2.5
24V1 0   2.3
24V2 0   4
24V3 0   5
24V4 0 8 17.9
Ripple+Noise(peak to peak) 24VS1-1     290 mV  
24VS2     290
24VS1-2     290
24V1     290
24V2     290
24V3     290
24V4     290
Output power       880 W  
Output efficiency 85       %  
Turn-on/down overshoot       25 V  
Output raise time       200 mS  
Ambient
Parameter   Min. Typ. Max. Unit Remark
Operating temperature   0   55 ºC  
Storage temperature   -20   65 ºC
Operating Relative humidity   10   90 %
Storage relative humidity   8   90 %
Altitude   0   5000 m
Atmosphere pressure   70   106 KPa
Cooling Inside the fan comes with heat
Protection
Input under voltage protection 130   140 Vac  
Input under voltage protection recovery 140   150
Input over voltage protection 276   288
Input over voltage protection recovery 262   272
DC Output over voltage protection 26   36
DC Output limited current protection 24VS1-1 5.3   8.5 A Auto recovery
24VS2 3   5
24VS1-2 3   5
24V1 3.8   6
24V2 5   8
24V3 12   16
24V4 28   34
Short-curcuit protection Long-term short-curcuit,auto recovery.
Over temperature protection TH2:88~98ºC,protection
<
85ºC,recovery
ºC
 
 
EMC&Others
Parameter Standard requirement
Radiation  Emission(CE) EN55022 - Class B 
Conduction interference(RE) EN55022 - Class B 
surge EN61000-4-5  LEVEL 3,line-line2KV,line-earth2KV
Electrostatic discharge (ESD) EN61000-4-2 Contact discharge±6KV,Air discharge±8KV
Radiation immunity (RS) EN/IEC 61000-4-3  Test frequency:80MHz~1000MHz,1.4GHz~2GHz;Electric field strength:3V/m;  Amplitude modulation:80%AM(1KHz)
Conduction immunity (CS) EN/IEC 61000-4-6  Test frequency:0.15MHz~80MHz,Test strength:3V;Amplitude modulation:80%AM(1KHz)
Fast transient bursts EN/IEC 61000-4-4  ±2KV
Voltage sags andshort interruptions EN/IEC61000-4-11  Fell to 70% UT,Duration 500ms;Fell to 0% UT,Duration 20ms;Criterion B,Criterion C
vibration
Project Operating During shipping
Vibration 4.9m/s2(0.5G) 19.6m/s2(2G)
Shock 49m/s2(5G) 98m/s2(10G)
Anti-moisture GB/T2423-1993 Damp heat test,24~45ºC95%RH,48h
Anti - mold GB/T2423.16-1999 Mold experiment, Level2
MTBF ≥200,000h
Working lifetime 65000H
Return rate of year ≤1%
Smell No semll harmful to health
Environment protection RoHS&VCCI-A
Safty UL/3C