Customization: | Available |
---|---|
Condition: | New |
Certification: | ISO |
Still deciding? Get samples of US$ 1500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input | ||||||
Parameters | Min. | Typ. | Max. | Unit | Remark | |
DC CHARGER (PV) |
Input voltage range | 100 | 300 | Vdc | Compatible with light energy, wind energy, DC generation 3 channels input, with MPPT, MPPT tracking accuracy is not less than 90%. Input 100V~ 150V, output current derating 26A, recovery voltage 154±5V | |
Output rated voltage | 48 | 57.6 | Vdc | |||
Output current | 32 | A | ||||
Output efficiency | 85 | 88 | % | Test with full load | ||
AC CHARGER | Input voltage range | 90 | 220 | 280 | Vac | Input 149V ~ 154V, output current derating 26A. Recovery voltage 160± 5V |
Input rated voltage | 120 | Vac | ||||
Input voltage frequency | 57 | 60 | 63 | Hz | ||
Power factor | 0.99 | |||||
Output voltage | 48 | 57.6 | Vdc | |||
Output current | 50 | A | ||||
Output efficiency | 92 | % | Test with full load |
Output | ||||||
Parameters | Min. | Typ. | Max. | Unit | Remark | |
AC(OUT) INVERTER OUTPUT | Output voltage range | 115 | 120 | 125 | Vac | Output max. power 3300W |
Output rated voltage | 120 | Vac | ||||
Output voltage range | 57 | 60 | 63 | Hz | ||
Output current | 30 | A | ||||
Output efficiency | 86 | % | Test with full load | |||
AC bypass output | Output rated voltage | 90 | 164 | Vac | With the common inverter output. The mains will supply power to the equipment when the main is available. It will transfer to inverter output when no mains input or mains over/ under voltage |
|
Output voltage frequency |
60 | |||||
Output current | 30 | A | ||||
BAT+ BAT- (OUT) |
Output voltage | 48 | Vdc | Battery direct output, with short circuit, current limiting protection. | ||
Output current | 5 | A | ||||
DC1+ DC2+ DC3+ GND (OUT) |
Output voltage | Output interface voltage is same with the input PV voltage | Vdc | @PV input, PV input power is greater than DC CHARGER max power, willprovide the external output interface |
Protection | ||||||
Parameters | Min. | Typ. | Max. | Unit | Remark | |
Power Module | Over temperature protection |
The power supply module has the function of over temperature protection. When the main radiator temperature too high and up to over temperature protection set point, turn off the output, temperature hysteresis is about 10ºC | ||||
Output over current protection |
Each module of the power supply has the function of over power protection and short circuit protection. |
Battery management function | ||
Battery management | DC charging | With MPPT, use the maximum power to charge |
AC charging | AC constant current charging firstly, then constant voltage charging. | |
Over/under voltage protection |
Battery comes with BMS management. |
Insulation rating | |||
Parameter | Standard | Remark | |
DC CHARGER | Input- Chassis | 2120Vdc/10mA/60S | No flashover, no breakdown, removed grounding screws when testing |
Input- Output | 2120Vdc/10mA/60S | ||
Output- Chassis | 710Vdc/10mA/60S | ||
AC CHARGER | Input- Chassis | 4240Vdc/10mA/60S | No flashover, no breakdown, removed grounding screws when testing |
Input- Output | 2120Vdc/10mA/60S | ||
Output- Chassis | 710Vdc/10mA/60S | ||
AC(OUT) INVERTER | Input- Chassis | 2121Vdc /10mA/60S | Withdraw the corresponding voltage for 1 minute, leakage current≤ 10mA, no breakdown or flashover phenomenon |
Input- Output | 2121Vdc /10mA/60S | ||
Output- Chassis | 750Vdc /10mA/60S | ||
Insulation resistance |
Under normal atmospheric pressure, relative humidity 90%,Testing voltage: 500v dc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Environment | |||||
Parameter | Min. | Typ. | Max. | Unit | Remark |
Operating temperature | -10 | 40 | °C | ||
Extended operating temperature | -20 | 50 | °C | ||
Storage temperature | -10 | 60 | °C | ||
Relative humidity | 90 | % | |||
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling mode | Fan cooling | ||||
Waterproof & dustproof | Under the following dust environment, the equipment can operate normally: Diameter> 5um, dust concentration≤3×104 grain /m3, Dust particles are non conductive, magnetic and corrosive. This product is without waterproof function. |