Find Similar Products

Basic Info.

Model NO.
GPESS-48100-302L-A
Specification
538*518*612 mm, 548*528*622 mm
AC out Inverter Max Output Power
3300W
Battery Type
Lithium Battery
Battery Voltage
48V
Battery Capacity
100ah
Weight
≤165kg
Transport Package
Carton
Trademark
Goldpower
Origin
Shenzhen
HS Code
8504401990
Production Capacity
1000000 Pieces

Product Description

GPESS-48100-302L-A portable energy storage system consists of AC CHARGER,DC CHARGER, AC(OUT) INVERTER,FRONT PANEL(Monitor unit), 4 modules, 2 groups 48V 50Ah lithium battery.
4.8kwh Renewable Energy Pure off-Grid Standard Ess for Household

 
Input
Parameters Min. Typ. Max. Unit Remark
DC CHARGER
(PV)
Input voltage range 100   300 Vdc Compatible with light energy, wind energy, DC generation 3 channels input, with MPPT, MPPT tracking accuracy is not less than 90%. Input 100V~ 150V, output current derating 26A, recovery voltage 154±5V
Output rated voltage   48 57.6 Vdc
Output current     32 A
Output efficiency 85 88   % Test with full load
AC CHARGER Input voltage range 90 220 280 Vac Input 149V ~ 154V, output current derating 26A.
Recovery voltage
160± 5V
Input rated voltage   120   Vac
Input voltage frequency 57 60 63 Hz
Power factor   0.99    
Output voltage   48 57.6 Vdc
Output current     50 A
Output efficiency 92     % Test with full load
Output
Parameters Min. Typ. Max. Unit Remark
AC(OUT) INVERTER OUTPUT Output voltage range 115 120 125 Vac Output max. power 3300W
Output rated voltage   120   Vac
Output voltage range 57 60 63 Hz
Output current     30 A
Output efficiency 86     % Test with full load
AC bypass output Output rated voltage 90   164 Vac With the common inverter output. The mains will supply power to the equipment when the main is available. It will transfer to inverter output when no  mains input or mains over/ under voltage
 
Output voltage
frequency
  60    
Output current     30 A
BAT+ BAT-
(OUT)
 
Output voltage   48   Vdc Battery direct output, with short circuit, current limiting protection.
Output current   5   A
DC1+ DC2+ DC3+ GND
(OUT)
 
Output voltage Output interface voltage is same with the input PV voltage Vdc @PV input, PV input
power is greater than DC CHARGER max power, willprovide the external output interface
Protection
Parameters Min. Typ. Max. Unit Remark
Power Module Over temperature
 protection
The power supply module has the function of over temperature protection. When the main radiator temperature too high and up to over temperature protection set point, turn off the output, temperature hysteresis is about 10ºC
Output over current
protection
Each module of the power supply has the function of over power protection and short circuit protection.
Battery management function
Battery management DC charging With MPPT, use the maximum power to charge
AC charging AC constant current charging firstly, then constant voltage charging.
Over/under voltage
protection
Battery comes with BMS management.
Insulation rating
Parameter Standard Remark
DC CHARGER Input- Chassis 2120Vdc/10mA/60S No flashover, no breakdown, removed grounding screws when testing
Input- Output 2120Vdc/10mA/60S
Output- Chassis 710Vdc/10mA/60S
AC CHARGER Input- Chassis 4240Vdc/10mA/60S No flashover, no breakdown, removed grounding screws when testing
Input- Output 2120Vdc/10mA/60S
Output- Chassis 710Vdc/10mA/60S
AC(OUT) INVERTER Input- Chassis 2121Vdc /10mA/60S Withdraw the corresponding voltage for 1 minute, leakage current≤ 10mA, no breakdown or flashover phenomenon
Input- Output 2121Vdc /10mA/60S
Output- Chassis 750Vdc /10mA/60S
 
Insulation resistance
 
Under normal atmospheric pressure, relative humidity 90%,Testing voltage: 500v dc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ
Environment
Parameter Min. Typ. Max. Unit Remark
Operating temperature -10   40 °C  
Extended operating temperature -20   50 °C  
Storage temperature -10   60 °C  
Relative humidity     90 %  
Atmospheric pressure 70   106 KPa  
Altitude 0   3000 m  
Cooling mode Fan cooling
Waterproof & dustproof Under the following dust environment, the equipment can operate normally: Diameter> 5um, dust concentration≤3×104 grain /m3,
Dust particles are non conductive, magnetic and corrosive. This product is without waterproof function.


 