Customization: | Available |
---|---|
Output Type: | Triple |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Unit | Min | Typical | Max | Testing Conditions |
Input voltage range | Vac | 90 | 220 | 264 | |
Input voltage frequency range | Hz | 47 | 50 | 63 | |
Input current | A | 1.05 | 120Vac Input (average value) | ||
A | 0.55 | 230Vac Input (average value) | |||
Input rush current | A | 17 | 120Vac Input | ||
A | 23 | 230Vac Input | |||
Safe leakage current | mA | 0.7 | 120Vac Input | ||
mA | 1.4 | 230Vac Input | |||
Input fuse | 250Vac S 3.15A |
Output voltage | Output current range (air cooling) | Output current range (fan cooling) | Peak value current | Regulator precession | Load regulation | Voltage regulation | Ripple |
+5V | 0.1A~10.5A | 0.1A~13A | 14A | ≤±2% | ≤±2% | ≤±2% | ≤50mV |
+3.3V | 0A~10.5A | 0A~13A | 14A | ≤±2% | ≤±2% | ≤±2% | ≤50mV |
+12V | 0A~0.65A | 0A~0.8A | 0.8A | ≤±5% | ≤±5% | ≤±5% | ≤120mV |
Item | Unit | Min | Typical | Max | Testing Conditions |
Output Power | W | 70W | 20CFM fan cooling/output with full load | ||
W | 52.5 | Natural cooling/ output with full load | |||
Output Efficiency | % | 70 | - | 120Vac/65W | |
Temperature coefficient | /ºC | ±0.02% | |||
Dynamic responsive recover | ms | 200 | 25%~50%~25%,50%~75%~50%, 5% or 250mV,max.1ms, recover to1% |
Item | Unit | Min | Typical | Max | Recovery characteristics |
+5V output over-voltage protection | V | 5.625 | 6.25 | 6.875 | Invariable voltage protection. Auto recovery |
+3.3V output over-voltage protection | V | 3.71 | 4.125 | 4.54 | Auto recovery |
+12V output over-voltage protection | V | 13.5 | 15 | 16.5 | Auto recovery |
Short-circuit protection | A | Can be long time short-circuit, and recover automatically. Every output with rated load. |
Item | Level | Standards(or testing conditions) |
Insulation voltage (output to ground) |
500Vdc | 500Vdc/1Min / Leakage Current≤10mA |
Insulation voltage ( input to ground) |
1500Vac | 1500Vac/1Min / Leakage Current≤10mA |
Insulation voltage ( input to output) |
2500Vac | 2500Vac/1Min / Leakage Current≤10mA |
Insulation resistance | 10MΩ | Under normal atmospheric pressure, and when the relative humidity is 90%, and the testing voltage is DC 500v, for the power supply, the insulation resistance of input to output, input to ground, and output to ground is no less than 10MΩ. |
Item | Index requirements | Standards |
CE | CLASS B | EN55022 |
RE | CLASS A | EN55022 |
CS | LEVEL 3 | EN61000-4-6 |
RS | LEVEL 3 | EN61000-4-3 |
ESD | There is no influence on the operation of power supply when charge on the case after power supply is encased Tangent discharge:LEVEL 4 Air discharge:LEVEL 3 |
EN61000-4-2 |
EFT/B | LEVEL 3 | IEC61000-4-4 |
SURGE | LEVEL 3:line-line2KV Line-ground 4KV |
EN61000-4-5 |
Item | Index requirements | Performance |
Noise | The noise of power supply should be less than 55dB(A), the condition is in the range of input voltage and output voltage and current, the distance is 1 meter from front , back, right and left, and 1.5 meter from upper and underside. | Pass |
MTBF | 100,000H | |
Vibration | >Frequency : 5 to 9 Hz >Amplitude : 3.5mm,9~200Hz >Direction : 3 directions >Sweep time : 50minutes(50minute per one way) > acceleration:10m/s2, > there is no influence on power supply. |
Pass |
Shock | Half-sine wave,acceleration: 20G,Amplitude 11ms,Direction : 3 directions(X,Y,Z) 3 times per one direction |
Pass |
Dustproof | Has some function of dustproof | Pass |
Odor | No peculiar smell and deleterious gas | Pass |