Product Description

1. Specification

 
Environment
Parameter Min. Typ. Max. Unit Remark
Operation environment temperature -40   60 °C  
Chassis operation temperature -40   90 °C  
Storage temperature -40   85 °C  
Humidity 10   95 % Relative humidity,non condensing.
Altitude -60   4000 m For operation over 2500m(5000 ft),the operation temperature will be derated by 2ºC per 305m.
-200   13000 ft
Noise   45   dB  
 
Input
Parameter Min. Typ. Max. Unit Remark
Nominal operation voltage range 100   240 Vac  
Input voltage range 85 220 305 Vac  
Input startup voltage range 90   285 Vac  
Input frequency 47 50 63 Hz  
Input current     2.0 A 90Vac input, rated load.
Power factor   0.95     Nominal operation voltage range, rated load.
Aging voltage range 100   305 Vac Rated load.
 
Output
Parameter Min. Typ. Max. Unit Remark
Output voltage range 47 48 49 Vdc  
Output current range 0 2.5   A  
Rated load   2.5   A  
Stabilized voltage precision     ± 3 % Constant voltage output.
Load regulation     ±3 % Constant voltage output.
Regulation     ±1 % Constant voltage output.
Ripple (Vp-p)     800 mV Rated input/output. Test with a 0.1uF film capacitor and a 10uF capacitor, bandwidth of 20MHz.
 
Protection
Parameter Min. Typ. Max. Unit Remark
Output power 0 150   W  
Output efficiency 90 91   % 220Vac input/ full-load.
Temperature coefficient     ±0.02 %/ºC Constant voltage output.
Standby power comsuption   4   W 220Vac input/ no-load.
Startup output delay   3   S 220Vac input/ no-load.
Startup&shutdown overshoot     10 % Rated input voltage, rated load.
             

PF requirement ( Test under normal temperature)
  Full-load 80% load 50% load
Startup&shutdown overshoot 0.96 0.95 0.92

Load & Efficiency ( Test under normal temperature)
Input voltage frequency 50% load 80% load Full-load
220Vac / 50Hz 88% 89% 90%
 
Protection
Parameter Min. Typ. Max. Unit Remark
Output over-voltage protection point 52   57.5 V Test with no-load, auto-recoverable.
Output current-limiting protectioin point 2.7   3.5 A Auto-recoverable.
Output short-circuit protection         Auto-recoverable.
 
EMC and others
Parameter Standard Standard
ESD Air discharge8KV (Criterion B) EN61000-4-2: 2008
EN61547:1995+A1: 2000
Contact discharge6KV (Criterion B)
RS Test frequency:80MHz~1000MHz;Test intensity:3V/m;
Amplitude modulation:80%AM(1kHz) (Criterion A)
EN61000-4-3: 2008
EN61547:1995+A1: 2000
CS Test frequency:0.15 MHz~ 80 MHz, Test intensity:3V,Amplitude modulation:80%AM(1kHz) EN61547:1995+A1: 2000
IEC 61000-4-6: 2008
EFT/B ± 1KV(Criterion B) IEC 61000-4-4: 2004
EN61547:2000+A1: 2000
Surge Line-line ±4KV ( internal resistance 2Ω)(Criterion C)
Line-ground ±4KV(internal resistance 12Ω)(Criterion C)
EN61000-4-5: 2008 EN61547:1995+A1:2000
DIP Dip to70%Ut,duration:500ms( 25 cycles); Criterion B EN61547:1995+A1: 2000
IEC61000-4-11:2004
Dip to 40%Ut,duration :100ms( 5 cycles);Criterion C  
Dip to 0%Ut,duration: 10ms( half cycle);Criterion C  
CE Class B EN55015: 2006+A1:2007
RE Class B EN55015: 2006+A1:2007
 Magnetic Emission(MRE)
Limits for loop diameter (dBμA) 2 m
9KHz ~ 70KHz  88
70KHz ~ 150KHz  88 ~ 58*
150KHz ~ 2.2MHz  58 ~ 26*
2.2MHz ~ 3.0MHz  58
3.0MHz ~ 30MHz  22
EN55015: 2006+A1:2007
Current harmonics Class C IEC61000-3-2: 2006
Voltage fluctuation & flicker Pst 1.0;P1t 0.65; dc3.3%; dmax3.3%;
d(t) value not exceeding 4% when voltage variation duration >500mS
IEC61000-3-3: 2008

Remark:
Criterion A (for continuity):
  1. DC output range shall be accordant to normal work situation during interference;
DC output voltage fluctuation shall be within ±10%.
b) There shall not be alarms, failure indication ( power failure or protection failure) or failure indicatioin
after interference.
Criterion B (for transience):   
1. DC output voltage shall not exceed the values belowed:
1) For -48V DC: -60V;
2) For-60V DC: -75V;
2. Spikes during interference shall not be considered.
3. There shall not be alarms, failure indication ( power failure or protection failure) or failure indicatioin
after interference.
4. Recover to normal function after interference.
Criterion C (for interruption):
The temporary lose of function is allowed, the function shall be recoverable automatically or manually, as well as by operation.
Criterion R (for susceptibility)
There shall not be damage or other interruption during test, such as software damage or improper operation of protecting units. The unit shall operate appropriately within specified range( not necessarily during process of test) after  transient electromagnetic phenomenon finished. The interference may result in actions of fuse or other device defined, and shall be replaced or reset before recovering to normal operation state. 

 
Safety & Insulation Rating
Parameter Standard Remark
Insulation voltage
(input -output)
3000Vac Durable for 50Hz,3000V AC voltage for 1min,
leakage current10mA.
There shall be no flashover or breakdown.
The discharge tube shall be removed before test.

 
Insulation voltage
(input -ground)
1500Vac Durable for 50Hz,1500V AC voltage for 1min,
leakage current10mA.
There shall be no flashover or breakdown.
The discharge tube shall be removed before test.
Insulation voltage
(output -ground)
500Vac Durable for 500V DC voltage for 1min,
leakage current10mA.
There shall be no flashover or breakdown.
The discharge tube shall be removed before test.
Insulation resistance 10MΩ Under normal atmosphere, relative humidity: 90%, testing  voltage:500V, the insulation resistance of AC&DC-ground and AC-DC of the shall be more tham 10MΩ.
 Safety Certification Meet the requirement of IEC61347-1,IEC61347-2-3,UL8750 Standard.
     
 
Mechanical specifications
Dimension(mm) 2180.5)*1010.5)*43.30.5)mm
Weight(kg) 1.2Kg