Input | ||||||
Parameter | Min. | Typical | Max. | Unit | Remark | |
Input voltage range | 40 | 48 | 60 | Vac | ||
Input current | 60 | A | ||||
Output | |||||
Parameter | Min. | Typical cal | Max. | Unit | Remark |
System output voltage | 380 | Vdc | |||
System total output current | 6.3 | A | |||
Regulation | ±1 | % | |||
Load regulation | ±1 | % | |||
Line regulation | ±1 | % | |||
Noise voltage (Vp-p) | 2 | V | Within 20MHZ | ||
Output power | 2400 | W | |||
Output efficiency | 90 | % | 48Vdc input | ||
Start-up time | 3 | 8 | S | ||
Over/under shoot @ start-up/shutdown | ±10 | % | |||
Hold up time | 10 | ms | |||
Current sharing unbalance | ±5 | % |
Ambient | |||||
Parameters | Min | Typical | Max | Unit | Remark |
Operating temp. | -5 | 55 | °C | Start up with no load @-5°C De-rating work when temperature is more than 55ºC |
|
Storage temp. | -40 | 80 | °C | ||
Humidity | 10 | 90 | % | Relative humidity, non-condensing | |
Atmospheric pressure | 70 | 106 | kpa | ||
Altitude | -60 -200 |
4000 13000 |
m ft |
For operation above 2500m (5000 ft.), the maximum operation temperature is derated by 2°C. per 305m (1000 ft.) | |
Earthquake rating | 4 | Zone | |||
Noise | 45 | dB | Relative to fan speed, load and ambient temperature | ||
Harmonic emission | EN/IEC61000-3-2 | ||||
Radiated emission | EN55022 - Class B | ||||
Conducted emission | EN55022 - Class B | ||||
ESD | EN/IEC 61000-4-2 Level 3 (Contact Discharge 6 kV, Air Discharge 8 kV). | ||||
Radiated immunity | EN/IEC 61000-4-3 Level 3 (10 V/m). | ||||
Conducted immunity | EN/IEC 61000-4-6 Level 3 (10Vrms). | ||||
Lightning surge Failure free Damage free |
EN/IEC61000-4-5 Level 4 (Common mode: 4Kv, Differential mode: 2kV). ANSI C62.41 Level A3 (Common mode and differential mode 6kV) |
||||
Insulation resistance | Insulation resistance between DC part and chassis shall be 10MΩ or more (Testing voltage: 500Vdc) | ||||
Dielectric strength | DC voltage: 500Vdc Leakage current: ≤10mA no break down and flashover within 1Min. |
Protection | |||||
Item | Unit | Min | Typical | Max | Recovery property |
Output current-limiting | A | 6.8 | 7.2 | ||
Short circuit | A | Long-term short circuit permissible. Hiccup when short circuit is detected. Shutdown if short circuit remains after 5min hiccup. |
|||
Thermal protection | ºC | DC output will be cut off when the module temperature reaches 90ºC. |
Mechanical spec. | |
Length (in./mm) | 16.96/430.7 |
Width (in./mm) | 16.56/420.7 |
Height (in./mm) | 6.72/170.8 |