Customization: | Available |
---|---|
Output Type: | Multiple |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Unit | Min | Typical | Max | Testing Conditions |
Input voltage range | Vac | 145 | 220 | 290 |
Output voltage | Output voltage range | Output current range | Regulator precession | Load regulation | Voltage regulation | Ripple |
+27V | 26.8V~27.4V | 0A~10A | ≤±2% | ≤±2% | ≤±1% | ≤50mV |
+12V | 11.88V~12.2V | 0A~6A | ≤±2% | ≤±2% | ≤±1% | ≤30mV |
+5V | 4.95V~5.15V | 0A~1A | ≤±2% | ≤±2% | ≤±1% | ≤30mV |
MODEM | 11.8V~12.25V | 0A~1.2A | ≤±2% | ≤±2% | ≤±1% | ≤30mV |
Item | Unit | Technology requirement | Remark |
Charge voltage | V | 24V plumbic acid battery BAT1, 26.5V~27.5V | VIN=145V~290Vac,all load conditions |
24V lithium battery BAT2, 24V~24.6V | |||
Charge current | A | 24V plumbic acid battery BAT1, 0A~1.5A | VIN=145V~290Vac, all load conditions |
24V lithium battery BAT2, 0A~0.3A | |||
The point of under-voltage protection | V | 24V plumbic acid battery BAT1, 21.5V~22.5V | +27V with 1A,others without load |
24V lithium battery BAT2, 17V~17.5V | +5 with 1A,others without load |
Item | Unit | Min | Typical | Max | Testing Conditions |
Output Power | W | - | 400 | ||
Output Efficiency | % | 80 | - | Rated input/output | |
Temperature coefficient | /ºC | ±0.02% |
Item | Unit | Min | Typical | Max | Recovery characteristics |
Input over-voltage protection | V | 290 | 305 | +27V with 4A,others without load. | |
The recovery point of input over-voltage protection | V | 280 | 290 | ||
Input under-voltage protection | V | 135 | 145 | +27V with 4A,others without load. | |
The recovery point of input under-voltage protection | V | 150 | 165 | ||
+27V output over-voltage protection | V | 29 | 31 | ||
+27V output limited current protection | A | 14 | 18 | Rated load, output the accumulator BAT1, limit the current below 24V, other outputs with min. load. | |
+9V output limited current protection | A | 6 | 9 | Rated load, outputs with min. load, every output limit current by each. | |
+5V output limited current protection | A | 2 | 5 | ||
MODEM output limited current protection | A | 2 | 5 | ||
Over-heating protection | ºC | 95 | 105 | Auto recovery | |
The current of short-circuit protection(+27V) | A | 10 | Rated input, every output is short circuit. | ||
The current of short-circuit protection (+9V) | A | 10 | |||
The current of short-circuit protection (+5V) | A | 5 | |||
The current of short-circuit protection (MODEM) | A | 5 |
Item | Level | Standards(or testing conditions) |
Insulation voltage ( output to ground) |
500Vdc | 500Vdc /1Min / Leakage Current≤10mA |
Insulation voltage ( input to ground) |
2000Vac | 2000Vac /1Min / Leakage Current≤10mA |
Insulation voltage ( input to output) |
3000Vac | 3000Vac /1Min / Leakage Current≤10mA |
Insulation resistance | 2MΩ | Under normal atmospheric pressure, and when the relative humidity is 90%, and the testing voltage is DC 500v, for the power supply, the insulation resistance of input to output, input to ground, and output to ground is no less than 2MΩ. |
grounding resistance | 0.1Ω | The grounding resistance of each power supply is less than 0.1Ω |
Tangent current | 1.5mA | The tangent current of each power supply is less than 1.5mA |
Item | Index requirements | Standards |
CE | CLASS A | EN55022 |
RE | CLASS A | EN55022 |
ESD | There is no influence on the operation of power supply when charge on the case after power supply is encased Tangent discharge:±8KV Air discharge:±4KV/±15KV |
EN61000-4-2 |
SURGE | LEVEL 3:Line-line 2KV Line-ground 4KV |
EN61000-4-5 |
Item | Index requirements | Performance |
Noise | The noise of power supply should be less than 55dB(A), the condition is in the range of input voltage and output voltage and current, the distance is 1 meter from front , back, right and left, and 1.5 meter from upper and underside. | Pass |
MTBF | 100,000H | |
Vibration | >Frequency : 5 to 9 Hz >Amplitude : 3.5mm,9~200Hz >Direction : 3 directions >Sweep time : 50minutes(50minute per one way) > acceleration:10m/s2, > there is no influence on power supply. |
Pass |
Shock | Half-sine wave,acceleration: 20G,Amplitude 11ms,Direction : 3 directions(X,Y,Z) 3 times per one direction |
Pass |
Dustproof | Has some function of dustproof | Pass |
Odor | No peculiar smell and deleterious gas | Pass |